Results 71 to 80 of about 43,525 (332)
VMAT testing for an Elekta accelerator [PDF]
Volumetric‐modulated arc therapy (VMAT) has been shown to be able to deliver plans equivalent to intensity‐modulated radiation therapy (IMRT) in a fraction of the treatment time. This improvement is important for patient immobilization/ localization compliance due to comfort and treatment duration, as well as patient throughput.
Kaurin, Darryl G.L. +3 more
openaire +2 more sources
Purpose This study aimed to improve the safety and accuracy of radiotherapy by establishing tolerance (TL) and action (AL) limits for the gamma index in patient‐specific quality assurance (PSQA) for intensity‐modulated radiation therapy (IMRT) and ...
Jia Deng +4 more
semanticscholar +1 more source
This study is to report 1) the sensitivity of intensity modulated radiation therapy (IMRT) QA method for clinical volumetric modulated arc therapy (VMAT) plans with multi-leaf collimator (MLC) leaf errors that will not trigger MLC interlock during beam ...
Xu Zhengzheng +3 more
doaj +1 more source
Background: External beam radiotherapy (EBRT) is essential in the management of locally advanced cervical cancer (LACC). Volumetric modulated arc therapy (VMAT) is thought to achieve higher conformity to the planned target volume (PTV) and better sparing
Visham Bhagaloo +3 more
doaj +1 more source
Novel hybrid approaches for chest wall irradiation show promising outcomes regarding target coverage and sparing organs at risk (OARs). In this systematic review, we compared hybrid volumetric modulated arc therapy (H-VMAT) or hybrid intensity-modulated ...
Zainab Alsaihaty +3 more
semanticscholar +1 more source
Purpose: This retrospective planning study aimed to verify the usefulness of a clinically available method, dynamic swing arc (DSA), a noncoplanar volumetric modulated arc therapy (VMAT) technique, of the new accelerator OXRAY for head and neck squamous ...
Kouta Hirotaki, MS +8 more
doaj +1 more source
Commissioning and verification of a 3D Monte Carlo independent calculation software for O-ring linac systems. [PDF]
Abstract Background O‐ring linac systems improve radiotherapy efficiency but require rigorous pretreatment verification due to increased delivery uncertainty in IMRT/VMAT. Existing methods face limitations: measurement‐based approaches incur setup errors, while calculation‐based methods (e.g., Monte Carlo) need machine‐specific validation per AAPM TG ...
Meng X +9 more
europepmc +2 more sources
Dopamine antagonists induce dopamine receptor supersensitivity. This may manifest in late-appearing movement disorders (tardive dyskinesia (TD). VMAT-2 inhibitors reduce dopaminergic transmission but have limited activity at postsynaptic receptors and so
A. Connolly +4 more
semanticscholar +1 more source
Investigation of VMAT Algorithms and Dosimetry [PDF]
{"references": ["Gregoire V, De neve W, Eisbruch A, Lee N, Van den Weyngaert D, Van Gestel D. Intensity modulated radiation therapy for Head and Neck carcinomas. The Oncologist. 2007; 12: 555-564.", "Braam P, Terhaard C, Roesink J. Intensity Modulated Radiotherapy significantly reduces xerostomia compared with conventional radiotherapy.
openaire +2 more sources
The purpose of this study was to compare hybrid intensity-modulated radiotherapy (IMRT) and volumetric-modulated arc therapy (Hybrid IMRT/VMAT), with non-coplanar (nc) IMRT and nc-VMAT treatment plans for unresectable olfactory neuroblastoma (ONB ...
V. Raturi +15 more
semanticscholar +1 more source

