Results 21 to 30 of about 3,553 (222)

Comparison of clinic-radiological and functional outcome of intra articular distal end radius fractures managed by volar locking plate versus external fixation [PDF]

open access: yes, 2021
Background: Distal end radius (DER) fractures are most common fractures in upper limb. Intra articular fractures can be managed either by open reduction and internal fixation by volar locking plate or can be managed by closed reduction and external ...
Ghani, Abdul   +4 more
core   +2 more sources

Volar locking plate: Age related outcomes and complications

open access: yesJournal of Clinical Orthopaedics and Trauma, 2020
There is no unanimity for the treatment of distal radius fractures in older people. The purpose of our study is to assess the efficacy of volar locking plate for the treatment of unstable distal radius fractures in older independent individuals.A retrospective comparative study of 105 patients.
Muhammad, Ali Fazal   +2 more
openaire   +3 more sources

Volar Locking Plate Fixation for Distal Radius Fractures by Intraoperative Computed Tomographic–Guided Navigation

open access: yesJournal of Hand Surgery Global Online, 2020
Purpose: Unstable distal radius intra-articular fractures require restoration of alignment. Exact fixation of intra-articular fragments is ideal. Here, we employed intraoperative computed tomography (CT) navigation to insert screws accurately in the ...
Akira Kawabata, MD   +3 more
doaj   +1 more source

Cost effectiveness of treatment with percutaneous Kirschner wires versus volar locking plate for adult patients with a dorsally displaced fracture of the distal radius: Analysis from the DRAFFT trial [PDF]

open access: yes, 2015
We present an economic evaluation using data from the Distal Radius Acute Fracture Fixation Trial (DRAFFT) to compare the relative cost effectiveness of percutaneous Kirschner wire (K-wire) fixation and volar locking-plate fixation for patients with ...
Achten, J   +6 more
core   +1 more source

Surgical Treatment of Unstable Distal Radius Fractures With a Volar Variable-Angle Locking Plate: Clinical and Radiological Outcomes [PDF]

open access: yes, 2016
Background: Unstable distal end radius fractures are difficult to manage and so various treatment modalities have been described. The use of variable-angle locking plates is promoted for the management of these fractures.
Farooque, K.   +3 more
core   +1 more source

Evaluating the necessity of bone augmentation for distal radius fracture fixed with a volar locking plate: a retrospective study

open access: yesBMC Musculoskeletal Disorders, 2020
Background Multiple approaches for fixation of distal radius fractures exist; nonetheless, there is no consensus on the optimal treatment for these injuries.
Feng-Shuo Chang   +4 more
doaj   +1 more source

Characteristics of two different locking compression plates in the volar fixation of complex articular distal radius fractures [PDF]

open access: yes, 2013
Objectives: To investigate the differences of open reduction and internal fixation (ORIF) of complex AO Type C distal radius fractures between two different models of a single implant type. Methods: A total of 136 patients who received either a 2.4 mm (n
AudigĂ©, L.   +6 more
core   +1 more source

Functional outcome of volar variable angle locking compression plate in distal end radius fractures: A retrospective case record analysis

open access: yesJournal of Orthopaedic Diseases and Traumatology, 2023
Background: Distal end-of-radius fractures are one of the most common fractures seen worldwide, accounting for approximately one-sixth of all fractures.
K M Pawan Kumar   +2 more
doaj   +1 more source

Avoiding complication of volar locked plates [PDF]

open access: yesBMC Proceedings, 2015
Volar locking plates are designed to improve and maintain anatomic alignment, even in patients with dorsal comminution and poor metaphyseal bone quality. Its widespread use led to specific complications. Most part is related to tendon, nerve and complex regional pain syndrome [1] and could be avoided by meticulous attention to detail and surgical ...
openaire   +1 more source

A new volar plate made of carbon-fiber-reinforced polyetheretherketon for distal radius fracture: analysis of 40 cases [PDF]

open access: yes, 2014
BACKGROUND: Implants based on the polyetheretherketon (PEEK) polymer have been developed in the last decade as an alternative to conventional metallic devices. PEEK devices may provide several advantages over the use of conventional orthopedic materials,
Adani, Roberto   +4 more
core   +1 more source

Home - About - Disclaimer - Privacy