Results 41 to 50 of about 2,450 (178)

High Aspect Ratio, Superconducting Vacuum Gap Capacitor NEMS with Plate Distances Down to 32 nm

open access: yesAdvanced Materials Technologies, Volume 10, Issue 18, September 18, 2025.
Fabrication of aluminium vacuum gap capacitor based NEMS is investigated with a free to move top electrode. To avoid collapse of the top electrode vertical stress gradient is controlled through sputter parameters. The result is wafer‐level high‐yield fabrication of vacuum gap capacitors with radii between 7 µm and 30 µm and integrated piezoactuators. A
Ioan Ignat, Daniel Platz, Ulrich Schmid
wiley   +1 more source

Surgical gestures—An emerging field for surgical assessment and training

open access: yesUroPrecision, Volume 3, Issue 3, Page 130-135, September 2025.
Abstract As surgical training shifts from a traditional method to a more standardized approach, objective analysis and assessment of surgeon performance has become a key focus. Surgical gestures, defined as the smallest independent units of instrument‐tissue interaction, offer a quantifiable way to analyze surgical performance.
Runzhuo Ma
wiley   +1 more source

Treatment of Unstable Scaphoid Nonunion Using Volar Locking Plate

open access: yes, 2020
14th Triennial Congress of the International Federation of Societies for Surgery of the Hand (IFSSH), 11th Triennial Congress of the International Federation of Societies for Hand Therapy (IFSHT), 11th Triennial Congress of the International Federation of Societies for Hand Therapy (IFSHT)
Kwon, YW, Park, JW, Choi, IC, Park, JH
openaire   +1 more source

Treatment of Distal Radius Fractures with Volar Locking Plate

open access: yesOrthopedics & Traumatology, 2009
掌側ロッキングプレートを使用して治療を行った橈骨遠位端骨折の治療成績を検討した.平成17年6月から平成19年10月に当院で手術を行った28例29手を対象とした.経過観察期間は平均15カ月で,手術時平均年齢は19~92歳(平均65.7歳)であった.骨折型はAO分類Type A2:4例,A3:5例,C1:8例,C2:6例,C3:6例であった.プレートはLC-DRPを使用した.全例で合併症なく骨癒合が得られた.最終観察時のX線学的評価では僅かな矯正損失を認めたが概ね良好な整復位を保持できた.臨床成績評価はMayoの評価法を用い,Excellent 19例,Good 6例,Fair 4例であった.本骨折の評価は術後約1年頃での臨床評価が望ましいと考えた.
Daisuke Tanino   +2 more
openaire   +2 more sources

Changes in Nerve Conduction Studies After Distal Radius Fracture Fixation Using a Volar Approach and Locked Plate [PDF]

open access: gold, 2020
Cory Demino   +5 more
openalex   +1 more source

Volar Locking Plate Breakage after Nonunion of a Distal Radius Osteotomy

open access: yesCase Reports in Medicine, 2016
We report a 38-year-old male with a nonunion followed by plate breakage after volar plating of a distal radius osteotomy. Volar locking plates have added a new approach to the treatment of distal radius malunions, due to a lower morbidity of the surgical approach and the strength of the final construction, allowing early mobilization and return to ...
Sergi Barrera-Ochoa   +4 more
openaire   +3 more sources

Comparison Between External Fixators and Fixed-Angle Volar-Locking Plates in the Treatment of Distal Radius Fractures [PDF]

open access: bronze, 2012
Alberto Jorge‐Mora   +6 more
openalex   +1 more source

ANATOMICAL STUDY OF VOLAR FACE OF DISTAL RADIUS AND COMPARISON WITH THE SHAPE OF LOCKING VOLAR PLATES

open access: gold, 2022
Luciana Cascão Lima   +3 more
openalex   +1 more source

Home - About - Disclaimer - Privacy