Results 11 to 20 of about 219,076 (264)
The improvement of the line Load-ability (LL) for voltage stability establishes the main criterion for distribution networks. The Distributed Generation (DG) resources play an important role in the supply of active and reactive power loads, bus voltage ...
Mohammad Kazeminejad, Mahdi Banejad
doaj +1 more source
This paper introduces a novel control strategy that merges integral sliding mode control with fuzzy adaptive PI control. This hybrid approach maximizes the benefits of both techniques to ensure voltage stability in DC microgrid.
Xinyu Zhang +6 more
doaj +1 more source
Sliding mode control based dynamic voltage restorer for voltage sag compensation
The reliability and efficiency of electrical power systems are critical for modern industries, which increasingly rely on electric machines and devices.
Ashraf K. Abdelaal +3 more
doaj +1 more source
Distributed secondary control of microgrids with unknown disturbances and non-linear dynamics
In this paper, the voltage and frequency regulation of microgrid with unknown disturbances and non-linear dynamics was studied. The disturbance observer was designed and the sliding mode control (SMC) method was used to realize the secondary regulation ...
Shunwei Hu +9 more
doaj +1 more source
For two-stage grid-connected photovoltaic (PV) system, if the low voltage ride through (LVRT) faults occur in the grid side, because the grid voltage falls to a relative low value and the output current is limited, then the output power of inverter ...
Yangyang Wu +10 more
doaj +1 more source
In a photovoltaic DC microgrid, the intermittent power supply of the distributed generation and the fluctuation of the load power will cause the instability of the bus voltage.
Siyuan Liu +7 more
doaj +1 more source
Internal Model Control Scheme-Based Voltage and Current Mode Control of DC–DC Boost Converter
In this work, a current mode control has been proposed for output voltage regulation of DC–DC boost converter. The proposed controller has a cascade control structure with two feedback loops.
Purnima Verma +3 more
doaj +1 more source
Single‐phase wind‐BES microgrid with seamless transition capability
A new control strategy for a wind‐BES (battery energy storage) microgrid is presented, which controls the power transfer and the mode of operation seamlessly from an islanded mode (IM) to the grid connected mode (GCM) and vice versa.
Tripurari Nath Gupta, Bhim Singh
doaj +1 more source
This paper proposes a novel cascade voltage-control method for DC variable-speed synchronous generators with a diode rectifier. In order to emphasize the necessity of the proposed method, the light-load voltage fluctuation problem that affects the ...
Sung-Soo Min, Kyoung-Min Choo
doaj +1 more source
Voltage and Current Programmed Modes in Control of the Z-Source Converter
The Z-source converter (ZSC) is an alternative power conversion topology that can both buck and boost the input voltage using passive components with improved reliability. Dynamic modeling of the ZSC from different perspectives has been studied. So far, based on these models, the dc-link voltage is controlled using direct measurement, or through ...
Gökhan Sen, Malik Elbuluk
openaire +2 more sources