Results 91 to 100 of about 733,401 (250)
This paper presents a system that provides photovoltaic generation as well as the ability to compensate current harmonics and voltage sags. The system can be controlled for current harmonics and reactive power compensation simultaneously by using a ...
Marcelo Cabral Cavalcanti +5 more
doaj +1 more source
Dynamic Voltage Restorer Against Balanced and Unbalanced Voltage Sags: Modelling and Simulation
This paper presents modelling aspects of several types of Dynamic Voltage Restorer (DVR) working against various voltage sags by simulation in PSCAD/EMTDC.
Saha, Tapan K., Nguyen, P. T.
core
Well XA‐1, completed at a true vertical depth of 11 156 m in the Shawan Sag of the Junggar Basin, is the deepest predominantly near‐vertical well drilled in a sedimentary basin. The figure shows the basin's tectonic framework and well location (a), a structural cross‐section spanning the Shawan Sag and adjacent uplifts (b), and the stratigraphic column
Fangkai Liu +3 more
wiley +1 more source
Research on the Impacts of Voltage Sag to Lighting Fixture
Based on ms level voltage sag generator, the performances on voltage sags of lamps occurred in different amplitudes, phase angles, durations are researched.
于希娟, 李洪涛, 赵贺
doaj
Proposal of voltage transient sag compensator with controlled gradational voltage
This paper presents a new concept for a voltage transient sag compensator and the experimental result of its 400-V-class compensator. This compensator is composed of the series connection of some inverter units with gradational output voltages. Because each output voltage is different by 2n times, an approximate sinusoidal voltage is generated by ...
Masaki Yamada +6 more
openaire +2 more sources
World's fastest 10 000‐m breakthrough: The XY‐22 well redefines deep‐earth access in the Tarim Basin
The Tarim Basin in northwestern China hosts one of the world's deepest petroleum systems, exemplified by the XY‐22 ultra‐deep well (bottom depth: 11 116 m; ~220°C, ~145 MPa). This study integrates tectonic mapping, geological cross‐sections, ultraviolet fluorescence microscopy, and optical photothermal infrared (OPTIR) spectroscopy to characterize ...
Qingwen Tan +4 more
wiley +1 more source
A New Algorithm for Relative Location of Voltage Sags Based on Voltage Measurements Only
This paper presents a tool easily implemented for relative location of voltage sags based on voltage measurements only. Voltage sags are considered from network faults in distribution systems only.
Blanco Solano, JAIRO Jairo
core +1 more source
This paper presents a voltage compensation-type current limiter based on a hybrid distribution transformer (HDT) structure, which integrates a three-winding transformer, AC/DC converter, DC/AC converter, current-limiting unit, bypass switches, and a ...
Ruiayo Wang +4 more
doaj +1 more source
This paper proposes a time-domain methodology based on the unscented Kalman filter to estimate voltage sags and their characteristics, such as magnitude and duration in power systems represented by nonlinear models.
Rafael Cisneros-Magaña +2 more
doaj +1 more source
This work developed a low‐temperature sludge hydrothermal coupled with gel crosslinking strategy which could upgrade the waste liquid generated from sewage sludge hydrothermal treatment into the hydrothermal‐liquid‐gel. The inventive hydrothermal‐liquid‐gel exhibited the enhanced pollutant removal capability, high synthetic stability, and superior ...
Zifan Liu +12 more
wiley +1 more source

