Results 21 to 30 of about 7,965 (345)
Current Control Reference Calculation Issues for the Operation of Renewable Source Grid Interface VSCs Under Unbalanced Voltage Sags [PDF]
23/04/13 MEB.
Soto-Sanchez, DE +7 more
core +1 more source
New Stationary Frame Control Scheme for Three Phase PWM Rectifiers Under Unbalanced Voltage Dips Conditions [PDF]
A new stationary frame control scheme for three-phase pulsewidth-modulation (PWM) rectifiers operating under unbalanced voltage dips conditions is proposed in this paper.
BOJOI, IUSTIN RADU +5 more
core +1 more source
Methodology for Determination of the Number of Equipment Malfunctions Due to Voltage Sags
This article deals with the assessment of the reliability of sensitive equipment due to voltage sags. The most frequent problems of power quality are voltage sags.
Alena Otcenasova +4 more
doaj +1 more source
A transformerless active voltage quality regulator with the novel three‐leg circuit
Voltage sags and momentary interruptions of power are the most severe voltage disturbances. Here, a tansformerless active voltage quality regulator with the novel three‐leg circuit is proposed to mitigate long duration and deep voltage sags.
Sen Wang +5 more
doaj +1 more source
Testing of three-phase equipment under voltage sags [PDF]
This paper provides insight into the testing of three-phase equipment exposed to voltage sags caused by faults. The voltage sag recovers at the fault-current zeros, leading to a ‘discrete’ voltage recovery, that is, the fault is cleared in different ...
Pedra Durán, Joaquín +7 more
core +1 more source
Power system faults can cause voltage sags that, if they are less than voltage sensitivity threshold of equipment, can lead to interruption of supply and lead to incurring of financial losses.
N Mbuli, R Xezile, JHC Pretorius, P Sowa
doaj +1 more source
The doubly fed induction generator (DFIG) and back-to-back converter are very sensitive to power quality disturbances in grid-connected wind energy conversion systems (WECSs).
Igor Rodrigues de Oliveira +2 more
doaj +1 more source
Voltage sag assessment using an extended fault positions method and Monte Carlo simulation
In this article, we propose an extended fault positions method combined with the Monte Carlo method to evaluate voltage sags. The distribution function SARFI is obtained by taking into account the randomness of (i) location of faults in lines, (ii ...
Jorge Washington Sagre +2 more
doaj +1 more source
This research paper addresses the issue of enhancing the operational availability of NPC three-level converter-based high-voltage direct current (HVDC) transport systems during alternating current (AC) grid fault conditions.
Ilyass El Myasse +3 more
doaj +1 more source
More stability and robustness with the multi-loop control solution for dynamic voltage restorer (DVR) [PDF]
This paper presents the application of dynamic voltage restorers (DVR) on power distribution systems for mitigation of voltage sags/swells at critical loads. DVR is one of the compensating types of custom power devices.
Abdelkhalek Othmane +4 more
doaj +1 more source