Results 51 to 60 of about 417,703 (296)
Proton currents constrain structural models of voltage sensor activation
The Hv1 proton channel is evidently unique among voltage sensor domain proteins in mediating an intrinsic ‘aqueous’ H+ conductance (GAQ). Mutation of a highly conserved ‘gating charge’ residue in the S4 helix (R1H) confers a resting-state H+ ‘shuttle ...
Aaron L Randolph +4 more
doaj +1 more source
Engineering of a genetically encodable fluorescent voltage sensor exploiting fast Ci-VSP voltage-sensing movements. [PDF]
Ci-VSP contains a voltage-sensing domain (VSD) homologous to that of voltage-gated potassium channels. Using charge displacement ('gating' current) measurements we show that voltage-sensing movements of this VSD can occur within 1 ms in mammalian ...
Alicia Lundby +4 more
doaj +1 more source
In this work, we present the design, laboratory tests, and the field trial results of a power-over-fiber (PoF) low power instrument transformer (LPIT) for voltage and current measurements in the medium voltage distribution networks.
Fabio R. Bassan +7 more
doaj +1 more source
Low Power Contactless Voltage Sensor for Low Voltage Power Systems [PDF]
Contactless measurements represent the desirable solution in many contexts, where minimal cabling is required or, in general, cabling is not possible. This paper presents a new contactless voltage sensor for low voltage power systems. It is based on a contactless capacitive probe, which surrounds the power cable.
Delle Femine, Antonio +4 more
openaire +4 more sources
ABSTRACT Background The Improving Population Outcomes for Renal Tumours of childhood (IMPORT) is a prospective clinical observational study capturing detailed demographic and outcome data on children and young people diagnosed with renal tumours in the United Kingdom and the Republic of Ireland.
Naomi Ssenyonga +56 more
wiley +1 more source
Ion channels as molecular targets of glioblastoma electrotherapy
Therapies with weak, non-ionizing electromagnetic fields comprise FDA-approved treatments such as Tumor Treating Fields (TTFields) that are used for adjuvant therapy of glioblastoma.
Tayeb Abed +6 more
doaj +1 more source
Thin-film temperature sensor [PDF]
Sensor measures rapid temperature changes in fluid streams. Sensor withstands contacts with various corrosive fluids, high fluid-flow rates, and turbulences caused by rapid changes in flow rates.
Gatewood, J. R., Maserjian, J.
core +1 more source
Overview of ionizing radiation effects in image sensors fabricated in a deep-submicrometer CMOS imaging technology [PDF]
An overview of ionizing radiation effects in imagers manufactured in a 0.18-μm CMOS image sensor technology is presented. Fourteen types of image sensors are characterized and irradiated by a 60Co source up to 5 kGy.
Estribeau, Magali +2 more
core +1 more source
ABSTRACT We present two pediatric cases of pediatric low‐grade gliomas (PLGG) with BRAF V600E mutations diagnosed and monitored using cerebrospinal fluid (CSF) liquid biopsy analyzed via digital droplet PCR (ddPCR), without tissue biopsy. Both patients were treated with dabrafenib and trametinib and monitored through clinical assessments, magnetic ...
Hannah Sultan +5 more
wiley +1 more source
ABSTRACT Ongoing evidence indicates increased risk of sarcopenic obesity among children and young people (CYP) with acute lymphoblastic leukemia (ALL), often beginning early in treatment, persisting into survivorship. This review evaluates current literature on body composition in CYP with ALL during and after treatment.
Lina A. Zahed +5 more
wiley +1 more source

