Results 11 to 20 of about 4,202,923 (210)

Dual Two-Level Voltage Source Inverter Virtual Inertia Emulation: A Comparative Study

open access: yesEnergies, 2021
In this paper, the virtual synchronous generator (VSG) concept is utilized in the controller of the grid-connected dual two-level voltage source inverter (DTL VSI). First, the topology of the VSG and the DTL VSI are presented.
Mohammad Ali Dashtaki   +4 more
doaj   +3 more sources

Harmonic Analysis and Mitigation of Low-Frequency Switching Voltage Source Inverter With Auxiliary VSI [PDF]

open access: yesIEEE Journal of Emerging and Selected Topics in Power Electronics, 2018
The output currents of high-power Voltage Source Inverters (VSIs) are distorted by the switching harmonics and the background harmonics in the grid voltage. This paper presents an active harmonic filtering scheme for high-power, low-frequency switching VSIs with an additional auxiliary VSI.
Frede Blaabjerg   +2 more
exaly   +2 more sources

Reduction and control of harmonic on three-phase squirrel cage induction motors with voltage source inverter (VSI) using ANN-grasshopper optimization shunt active filters (ANN-GOSAF)

open access: yesScientific African, 2023
El trabajo de investigación se centra en la reducción y el control de armónicos en un motor de inducción de jaula de ardilla trifásico (SCIM) que se acciona mediante un convertidor trifásico controlado por modulación de ancho de pulso (PWM) utilizando un método de filtros activos de derivación de optimización ANN-Grasshopper (ANN-GOSAF) recientemente ...
Emmanuel Eronu, Timothy Oluwaseun Araoye
exaly   +3 more sources

An 'active' passive-filter topology for low power DC/AC inverters [PDF]

open access: yes, 2011
This thesis was submitted for the degree of Doctor of Philosophy and awarded by Brunel University.This thesis presents a new output passive filter for voltage source inverter applications which is based on a shunt connected single tuned filter topology ...
Arman, Mahmoud Fayez
core   +7 more sources

Controlled Energy Flow in Z-Source Inverters

open access: yesEnergies, 2021
This paper proposes a method to reduce the output voltage distortions in voltage source inverters (VSI) working with impedance networks. The three main reasons for the voltage distortions include a discontinuous current in the coils of the impedance ...
Zbigniew Rymarski   +2 more
doaj   +1 more source

Mitigation of supply voltage disturbances with a load voltage-controlled inverter

open access: yesEngineering and Applied Science Research, 2021
The three-phase four-wire Voltage Controlled Voltage Source Inverter (VC-VSI) is proposed as a multi-function voltage compensator for supply voltage disturbances to improve the load voltage quality.
Hanny H. Tumbelaka
doaj   +1 more source

Common Architectures and Devices for Current Source Inverter in Motor-Drive Applications: A Comprehensive Review

open access: yesEnergies, 2023
When compared to the much more common voltage-source inverter (VSI), the current-source inverter (CSI) is rarely used for variable speed drive applications, due to its disadvantages: the need of a constant DC-link current, typically realized with a front-
Giovanni Luca Fidone   +6 more
doaj   +1 more source

A Novel H∞ Robust Control Strategy for Voltage Source Inverter in Microgrid

open access: yesFrontiers in Energy Research, 2021
The voltage control performance of the voltage source inverter (VSI) in a microgrid may change under different load conditions. However, in the case of traditional control strategies, the robustness of VSI is insufficient.
Hongtao Shi   +4 more
doaj   +1 more source

Comparative Study of Passivity, Model Predictive, and Passivity-Based Model Predictive Controllers in Uninterruptible Power Supply Applications

open access: yesEnergies, 2023
Voltage source converters are widely used in distributed generation (DG) and uninterruptible power supply (UPS) applications. This paper aims to find the controller that performs best when model changes occur in the system, showing insensitivity to ...
Shafquat Hussain   +4 more
doaj   +1 more source

Behavior of a Pentacle Connected Five-Phase IM Supplied by a Rectangular Voltage

open access: yesAdvances in Electrical and Electronic Engineering, 2020
The presented article deals with the steady-state analysis of five-phase Induction Motor (IM), which is supplied by rectangular voltage from a five-leg Voltage Source Inverter (VSI). The new proposed approach is derived from complex Fourier-series using
Pavel Zaskalicky
doaj   +1 more source

Home - About - Disclaimer - Privacy