Results 51 to 60 of about 4,202,923 (210)

Balanced Current Control Strategy for Current Source Rectifier Stage of Indirect Matrix Converter under Unbalanced Grid Voltage Conditions

open access: yesEnergies, 2016
This paper proposes a balanced current control strategy for the current source rectifier (CSR) stage of an indirect matrix converter (IMC) under unbalanced grid voltage conditions. If the three-phase grid connected to the voltage source inverter (VSI) of
Yeongsu Bak, June-Seok Lee, Kyo-Beum Lee
doaj   +1 more source

Parasitic Effects of PWM-VSI Control Leading to Torque Harmonics in AC Drives

open access: yesEnergies, 2021
Precise torque control without pulsations is one of the major quality issues in pulse-width modulated voltage-source inverter (PWM-VSI) drives. Theoretically, it could be postulated that at frequencies of some kHz, the machine’s inertia absorbs switching
Juriy Plotkin   +3 more
doaj   +1 more source

Accurate Inverter Error Compensation and Related Self-Commissioning Scheme in Sensorless Induction Motor Drives [PDF]

open access: yes, 2009
This paper presents a technique for accurately identifying and compensating the inverter nonlinear voltage errors that deteriorate the performance of sensorless field-oriented controlled drives at low speed.
Radu Iustin Bojoi   +10 more
core   +1 more source

Circulating Exosomes Drive Persistent Neuronal Dysfunction in Post‐Herpetic Neuralgia Patients

open access: yesAnnals of Neurology, EarlyView.
Proposed model of exosome‐mediated neuronal dysfunction in post‐herpetic neuralgia (PHN). (1) Circulating, non‐pathogenic exosomes maintain homeostatic processes in healthy skin, where sensory nerve fibers innervate the epidermis and dermis. (2) During acute zoster, reactivating varicella zoster virus (VZV) travels down neurites to the skin causing ...
Christy S. Niemeyer   +14 more
wiley   +1 more source

Control of Three Phase Two Stage LCL type Grid Interfaced PV Inverter [PDF]

open access: yesJournal of Electrical and Electronics Engineering, 2020
In this paper proposes the performance & control of three- phase two stage grid interfaced with LCL filter. The PV system output supplied to the DC voltage of voltage controlled inverter to the grid interfacing. In this work, LCL feature has been applied
SINGH Bipin   +2 more
doaj  

A Circulating-Current Suppression Method for Parallel-Connected Voltage-Source Inverters With Common DC and AC Buses [PDF]

open access: yesIEEE Transactions on Industry Applications, 2016
This paper presents a theoretical study with experimental validation of a circulating-current suppression method for parallel operation of three-phase voltage source inverters (VSI), which may be suitable for modular parallel uninterruptible power supply systems or hybrid AC/DC microgrid applications.
Wei, Baoze   +3 more
openaire   +3 more sources

Reference‐Superimposed Reconstruction (RS‐Recon) for Arterial Spin Labeling

open access: yesMagnetic Resonance in Medicine, Volume 96, Issue 6, Page 2685-2697, December 2026.
ABSTRACT Purpose Conventional arterial spin labeling (ASL) reconstruction suffers from sign‐flipping errors and/or noise bias under strong background suppression (BS), limiting SNR optimization. We propose reference‐superimposed reconstruction (RS‐recon) to enable ideal BS and robust signal recovery.
Jia Guo
wiley   +1 more source

DC Bus Control of Back-to-Back Connected Two-Level PWM Rectifier-Five-Level NPC Voltage Source Inverter to Torque Ripple Reduction in Induction Motor

open access: yesMATEC Web of Conferences, 2015
This paper proposes a regulation method of back-to-back connected two-level PWM rectifier-five-level Voltage Source Inverter (VSI) in order to reduce the torque ripple in induction motor.
Abdelkrim Thameur   +2 more
doaj   +1 more source

A Control for an Unbalanced 3-Phase Load in UPS Systems

open access: yesElektronika ir Elektrotechnika, 2018
Single input single output systems (SISO), which only control the output voltage of a voltage source inverter (VSI) using multi-loop feedback, are not sufficient in the event of a 3-phase unbalanced load.
Zbigniew Rymarski   +2 more
doaj   +1 more source

A novel approach to design of a power factor correction and total harmonic distortion reduction-based BLDC motor drive

open access: yesFrontiers in Energy Research, 2023
This study describes a novel approach to design of a power factor correction (PFC) and total harmonic distortion (THD) reduction-based brushless DC (BLDC) motor drive. The drive was designed to obtain a reduced THD for PFC.
Li Bin   +6 more
doaj   +1 more source

Home - About - Disclaimer - Privacy