Results 41 to 50 of about 3,306,600 (250)

Sparse Volumetric PZT Array with Density Tapering [PDF]

open access: yes2018 IEEE International Ultrasonics Symposium (IUS), 2018
Volumetric medical ultrasound imaging currently provides either high resolution or high frame rates. We propose a sparse array probe with only 256 elements that are density tapered. All elements are directly wired to an ultrasound engine, thus being flexible in transmission and reception. Here we present the design, realization, and characterization of
Vos, Hendrik J   +10 more
openaire   +1 more source

Artificial Intelligence in Systemic Sclerosis: Clinical Applications, Challenges, and Future Directions

open access: yesArthritis Care &Research, EarlyView.
Systemic sclerosis (SSc) is a rare autoimmune disease defined by immune dysregulation, vasculopathy, and progressive fibrosis of the skin and internal organs. Despite advances in care, major complications such as interstitial lung disease (ILD) and myocardial involvement remain the leading causes of morbidity and mortality.
Cristiana Sieiro Santos   +2 more
wiley   +1 more source

Volumetric breast density affects performance of digital screening mammography [PDF]

open access: yes, 2016
PURPOSE: To determine to what extent automatically measured volumetric mammographic density influences screening performance when using digital mammography (DM).
van Gils, CH   +38 more
core   +2 more sources

Agreement of Mammographic Measures of Volumetric Breast Density to MRI

open access: yesPLoS ONE, 2013
Clinical scores of mammographic breast density are highly subjective. Automated technologies for mammography exist to quantify breast density objectively, but the technique that most accurately measures the quantity of breast fibroglandular tissue is not known.To compare the agreement of three automated mammographic techniques for measuring volumetric ...
Hylton, Nola   +9 more
openaire   +5 more sources

Beyond Visual Scoring: Computational Computed Tomography Analysis for High‐Resolution Computed Tomography–Based Quantification of Interstitial Lung Disease in Inflammatory Rheumatic Disease

open access: yesArthritis Care &Research, EarlyView.
Interstitial lung disease (ILD) is a significant cause of morbidity and mortality in patients with inflammatory rheumatic disorders (IRDs). High‐resolution computed tomography (HRCT) is widely considered the gold standard for the noninvasive assessment of ILD; however, its interpretation is constrained by substantial interobserver variability and the ...
Alexander Pfeil   +7 more
wiley   +1 more source

Mechanochemical Synthesis and Characterization of Nanostructured ErB4 and NdB4 Rare‐Earth Tetraborides

open access: yesAdvanced Engineering Materials, Volume 27, Issue 6, March 2025.
ErB4 and NdB4 nanostructured powders are produced by mechanochemical synthesis. 5 h mechanical alloying and 4 M HCl acid leaching are used in the production. ErB4 and NdB4 powders exhibit maximum magnetization of 0.4726 emu g−1 accompanied with an antiferromagnetic‐to‐paramagnetic phase transition at about TN = 18 K and 0.132 emu g−1 with a maximum at ...
Burçak Boztemur   +5 more
wiley   +1 more source

Characterization of Defect Distribution in an Additively Manufactured AlSi10Mg as a Function of Processing Parameters and Correlations with Extreme Value Statistics

open access: yesAdvanced Engineering Materials, EarlyView.
Predicting extreme defects in additive manufacturing remains a key challenge limiting its structural reliability. This study proposes a statistical framework that integrates Extreme Value Theory with advanced process indicators to explore defect–process relationships and improve the estimation of critical defect sizes. The approach provides a basis for
Muhammad Muteeb Butt   +8 more
wiley   +1 more source

Microstructural Evolution and Vacancy Defect Formation in Mn–Mo–Ni RPV Steel Under Low Cycle Fatigue: Insights From EBSD and PALS

open access: yesAdvanced Engineering Materials, EarlyView.
Low‐cycle fatigue damage in Mn–Mo–Ni reactor pressure vessel steel is examined using a combined electron backscatter diffraction and positron annihilation lifetime spectroscopy approach. The study correlates texture evolution, dislocation substructure development, and vacancy‐type defect formation across uniform, necked, and fracture regions, providing
Apu Sarkar   +2 more
wiley   +1 more source

A Simplified Laminar Flow Model for the Pultrusion of Glass Fiber/Polyethylene Terephthalate Commingled Yarns

open access: yesAdvanced Engineering Materials, EarlyView.
A simplified thermoplastic pultrusion model is developed to predict thermal fields in glass fiber/polyethylene terephthalate (GF/PET) composites with reduced computational cost. By combining effective material homogenization, validation against literature data, and Gaussian‐process‐based optimization, the study reveals how heating limits, pulling speed,
Elder Soares   +3 more
wiley   +1 more source

ITS-90 density of water formulation for volumetric standards calibration

open access: yesJournal of Research of the National Institute of Standards and Technology, 1992
A new formulation of the density of air-saturated water as a function of temperature on the 1990 International Temperature Scale (ITS-90) is presented. Also, a new equation for calculating isothermal compressibility as a function of temperature on ITS-90 was developed.
Jones, Frank E., Harris, Georgia L.
openaire   +2 more sources

Home - About - Disclaimer - Privacy