Results 121 to 130 of about 15,485 (236)
The aim of the study was to present dosimetric comparison of image guided high-dose-rate brachytherapy (IGBT) with volumetric modulated arc therapy (VMAT) for head and neck cancer regarding conformity of dose distribution to planning target volume (PTV ...
Akiyama Hironori +6 more
doaj +1 more source
What's new? While treatment strategies for solid brain metastases have been relatively uniform across cancer subtypes, tailored approaches are warranted. In this observational study, intracranial recurrences after microsurgical resection occurred significantly earlier and more frequently at distant sites in patients with triple‐negative breast cancer ...
Jonathan Weller +14 more
wiley +1 more source
Purpose: This study aims to compare treatment plans created using RapidPlan and PlanIQ for twelve patients with prostate cancer, focusing on dose uniformity, dose reduction to organs at risk (OARs), plan complexity, and dose verification accuracy.
Shoma Nakano +6 more
doaj +1 more source
Application of volumetric modulated arc therapy (VMAT) in a dual-vendor environment
Background and Purpose The purpose of this study was to assess plan quality and treatment time achievable with the new VMAT optimization tool implemented in the treatment planning system Oncentra MasterPlan® as compared to IMRT for Elekta SynergyS ...
Weidner Karin +2 more
doaj +1 more source
Abstract Background Accurate heterogeneity correction in high‐precision radiotherapy relies on precise computed tomography (CT) number‐to‐density conversion via the Hounsfield unit look‐up table (HLUT). While physical properties of tissue‐equivalent materials are generally assumed consistent with manufacturer specifications, an independent audit ...
Minoru Nakao +5 more
wiley +1 more source
In vivo quality assurance of volumetric modulated arc therapy for ano-rectal cancer with thermoluminescent dosimetry and image-guidance [PDF]
To assess in vivo dose distribution using cone-beam computed tomography scans (CBCTs) and thermoluminescent dosimeters (TLDs) in patients with anal or rectal cancer treated with volumetric modulated arc therapy (VMAT)
Dipasquale, Giovanna +5 more
core +1 more source
Dual‐scan conformal cone‐beam CT for targeted image‐quality improvement using dynamic collimation
Abstract Background Cone‐beam computed tomography (CBCT) is routinely used for image guidance in radiation therapy, but conventional full‐field CBCT acquisition may expose anatomically irrelevant regions and generate substantial scatter, which degrades soft‐tissue contrast and limits the accuracy of target localization and adaptive radiotherapy ...
Yuxiang Liu +3 more
wiley +1 more source
Stereotactic radiosurgery (SRS) with volumetric modulated arc therapy (VMAT): interim results of a multi-arm phase I trial (DESTROY-2) [PDF]
To present the interim results of a phase I trial on stereotactic radiosurgery (SRS) delivered using volumetric modulated arc therapy (VMAT) in patients with primary or metastatic tumours in different extracranial ...
Ferro, Marica +12 more
core +1 more source
Abstract Background and purpose Anatomical changes during radiotherapy for nasopharyngeal carcinoma (NPC) frequently compromise target volume coverage while escalating dose delivery to organs at risk (OARs). In adaptive radiotherapy (ART), optimizing workflow efficiency to minimize clinical workload while maximizing patient benefit remains a ...
Zhenmei Cao +8 more
wiley +1 more source
Integration of biological factors in the treatment plan evaluation in breast cancer radiotherapy
Background/purpose: Tumor biology and patient smoking status have clear effects on the benefit of breast radiotherapy. This study developed treatment evaluation strategies that integrated dosimetry, tumor aggressiveness and smoking status for patients ...
Henrik Svensson +5 more
doaj +1 more source

