Results 71 to 80 of about 34,245 (334)

Multicriteria VMAT optimization

open access: yes, 2011
Purpose: To make the planning of volumetric modulated arc therapy (VMAT) faster and to explore the tradeoffs between planning objectives and delivery efficiency. Methods: A convex multicriteria dose optimization problem is solved for an angular grid of
Bedford   +37 more
core   +1 more source

Dosimetric comparison among dynamic conformal arc therapy, coplanar and non-coplanar volumetric modulated arc therapy for single brain metastasis.

open access: yesJournal of Radiation Research, 2021
In the delivery of stereotactic radiosurgery (SRS) by linear accelerator (LINAC), dynamic conformal arc therapy (DCAT) with non-coplanar beams is conventionally used. However, volumetric modulated arc therapy (VMAT) can improve target conformity, thereby
D. Torizuka   +3 more
semanticscholar   +1 more source

A dosimetric comparison of 3D conformal vs intensity modulated vs volumetric arc radiation therapy for muscle invasive bladder cancer

open access: yesRadiation Oncology, 2012
Background To compare 3 Dimensional Conformal radiotherapy (3D-CRT) with Intensity Modulated Radiotherapy (IMRT) with Volumetric-Modulated Arc Therapy (VMAT) for bladder cancer.
Foroudi Farshad   +9 more
doaj   +1 more source

Evaluation of Hybrid Arc and Volumetric-Modulated Arc Therapy Treatment Plans for Fractionated Stereotactic Intracranial Radiotherapy. [PDF]

open access: yes, 2018
PURPOSE: The study was aimed to compare hybrid arc and volumetric-modulated arc therapy treatment plans for fractionated stereotactic radiotherapy of brain tumors. METHODS: Treatment plans of 22 patients were studied.
Gunn, Vickie   +5 more
core   +1 more source

A retrospective comparison of intensity-modulated arc therapy and 3-dimensional conformal approaches in the planning of grade 3 gliomas [PDF]

open access: yes, 2018
Purpose: To evaluate the extent to which intensity-modulated arc therapy (IMAT) for high-grade gliomas is comparable with three-dimensional conformal radiotherapy (3DCRT) in relation to the dose delivered to normal brain tissue (NBT), planning target ...
Bernadette Foran   +6 more
core   +1 more source

A Novel Machine Learning Model for Dose Prediction in Prostate Volumetric Modulated Arc Therapy Using Output Initialization and Optimization Priorities

open access: yesFrontiers in Artificial Intelligence, 2021
Treatment planning for prostate volumetric modulated arc therapy (VMAT) can take 5–30 min per plan to optimize and calculate, limiting the number of plan options that can be explored before the final plan decision.
P. J. Jensen   +3 more
semanticscholar   +1 more source

Bioprinting Organs—Science or Fiction?—A Review From Students to Students

open access: yesAdvanced Healthcare Materials, EarlyView.
Bioprinting artificial organs has the potential to revolutionize the medical field. This is a comprehensive review of the bioprinting workflow delving into the latest advancements in bioinks, materials and bioprinting techniques, exploring the critical stages of tissue maturation and functionality.
Nicoletta Murenu   +18 more
wiley   +1 more source

Evaluation of dosimetric effect caused by slowing with multi-leaf collimator (MLC) leaves for volumetric modulated arc therapy (VMAT)

open access: yesRadiology and Oncology, 2016
This study is to report 1) the sensitivity of intensity modulated radiation therapy (IMRT) QA method for clinical volumetric modulated arc therapy (VMAT) plans with multi-leaf collimator (MLC) leaf errors that will not trigger MLC interlock during beam ...
Xu Zhengzheng   +3 more
doaj   +1 more source

Performance Comparison of Knowledge-Based Dose Prediction Techniques Based on Limited Patient Data. [PDF]

open access: yes, 2018
PurposeThe accuracy of dose prediction is essential for knowledge-based planning and automated planning techniques. We compare the dose prediction accuracy of 3 prediction methods including statistical voxel dose learning, spectral regression, and ...
Landers, Angelia   +4 more
core  

A clinical trial to compare a 3D‐printed bolus with a conventional bolus with the aim of reducing cardiopulmonary exposure in postmastectomy patients with volumetric modulated arc therapy

open access: yesCancer Medicine, 2021
We compared the dosimetry, application, and acute toxicity of a 3D‐printed and a conventional bolus for postmastectomy radiotherapy (PMRT) with volumetric modulated arc therapy (VMAT).
Yun Zhang   +9 more
semanticscholar   +1 more source

Home - About - Disclaimer - Privacy