Results 161 to 170 of about 28,726 (209)

Potential interactions between VSC HVDC and STATCOM

open access: yes2014 Power Systems Computation Conference, 2014
This paper analyses the dynamic behaviour of a power system with both FACTS and VSC HVDC, in particular, possible potential interactions between a STATCOM and a VSC in a point-to-point HVDC link. The investigation considers different STATCOM locations and VSC control strategies.
Shen, L.   +4 more
openaire   +2 more sources

VSC-HVDC Station With SSSC Characteristics

IEEE Transactions on Power Electronics, 2004
Commercial installations of voltage-source converter-high voltage direct current (VSC-HVDC) are now in service as asynchronous link and as underwater/underground DC transmission. The research reported in his paper is directed to providing VSC-HVDC with synchronizing power and damping power so that after a transient the steady-state is reached in ...
F. Al Jowder, B.T. Ooi
openaire   +1 more source

A Hybrid Simulation Model for VSC HVDC

IEEE Transactions on Smart Grid, 2016
The motivation for the presented research is based on the needs to develop new methods and tools for obtaining the information required to evaluate the mutual influence of HVDC and HVAC systems. This paper presents the specialized concept of a hybrid simulation for advanced modeling of VSC HVDC.
Yury S. Borovikov   +7 more
openaire   +2 more sources

VSC-HVDC Control System

2020
In the case of VSC-based HVDC transmission systems, the transfer of power is controlled in the same way as in the case of a classic HVDC transmission. The inverter side controls the active power, while the rectifier side controls the DC voltage [33, 56]. With classic HVDC, the reactive power cannot be controlled independently of the active power.
Nagwa F. Ibrahim, Sobhy S. Dessouky
openaire   +1 more source

VSC-HVDC Simulation Results

2020
The system considered in this book is given in Fig. 5.1. The HVDC system consists of two VSCs connected via a DC link. The control of converter VSC-1 is done by using DC voltage control, whereas the control of converter VSC-2 is done by active power control. In this chapter, the steady-state and transient behavior of control schemes in normal and fault
Nagwa F. Ibrahim, Sobhy S. Dessouky
openaire   +1 more source

The hybrid model of VSC HVDC

Electrical Engineering, 2019
The trend in semiconductor developments has made the high-voltage direct current (HVDC) technologies based on voltage source converters feasible. This type of convertor has a number of potential advantages compared with “classic” HVDC, but deep analysis should be carried out before its integration in electric power system. In this paper, the results of
Ruslan Ufa   +10 more
openaire   +1 more source

Modelling, Control and Simulation of VSC-HVDC Systems

2018 15th International Multi-Conference on Systems, Signals & Devices (SSD), 2018
The world is facing today a global energy transition challenge since developed countries need more energy for their economy growth in a framework of limited and poorly distributed energy resources. The Voltage Source Converter for High Voltage Direct Current (VSC-HVDC) is the most appropriate and efficient technology leading to accommodate more ...
Asma Rekik, Ghada Boukettaya
openaire   +1 more source

Review of VSC HVDC connection for offshore wind power integration [PDF]

open access: yesRenewable and Sustainable Energy Reviews, 2016
Voltage Source Converter (VSC) High Voltage Direct Current (HVDC) connection has become a new trend for long distance offshore wind power transmission.
Qiuwei Wu   +2 more
exaly   +2 more sources

Home - About - Disclaimer - Privacy