Results 251 to 260 of about 13,981 (280)
Some of the next articles are maybe not open access.

A low temperature water-cooled radiation calorimeter for estimation of concentrated solar irradiance

Solar Energy, 2018
Abstract Radiation calorimeter is a device for assessment of the incident local concentrated solar irradiance (CSI) onto a receiver surface. This is required to evaluate the performance of a concentrated solar thermal system using, for instance a volumetric receiver, for applications. In this paper a low-temperature water cooled radiation calorimeter
Ram Niwas Verma   +3 more
openaire   +1 more source

Shield Penetrating Water Cooled Bus Ducts for Radiation Resistant Magnets at J-PARC

IEEE Transactions on Applied Superconductivity, 2008
The high intensity proton accelerator facility J-PARC is now in its final stage of construction. Soon intense primary proton beams will be slowly extracted to an experimental hall (HD-hall) and transported to a production target. Since the radiation level around the target will be very high, the beam line tunnel needs to be surrounded by 2.5 m-5 m ...
E. Hirose   +16 more
openaire   +1 more source

Positron study of radiation embrittlement of steels used in water cooled, water moderated energy reactors

Applied Surface Science, 2006
Abstract Positron annihilation spectroscopy (PAS) lifetime study was applied in the evaluation of the microstructure parameters and degradation processes of nuclear reactor pressure vessel (RPV) steel surveillance specimens. Study was oriented to the material investigation of Russian WWER-1000 steels (15Kh2MNFAA and 12Kh2N2MAA) with higher Ni content
Vladimír Slugeň   +3 more
openaire   +1 more source

Thermal And Structural Analyses Of A Synchrotron Radiation X-Ray Monochromator With Liquid Gallium And Water Cooling

SPIE Proceedings, 1989
The finite element method is used in the thermal and structural analyses of a 3-channel silicon-crystal monochromator in a wiggler x-ray beam. Liquid gallium and water are used as coolants. Liquid gallium is fed into the monochromator by an induction pump designed and built for this purpose at Argonne National Laboratory.
A. M. Khounsary   +4 more
openaire   +1 more source

Analysis on the anti-corrosion of air radiator in water cooling system for high-power offshore wind turbine

2020 4th International Conference on HVDC (HVDC), 2020
Off-shore wind turbine is a new hot spot in the field of new energy. Due to the characteristics of high salt fog, high humidity and long sunshine time in the marine environment, the anti-corrosion performance of air radiator in the water cooling system of high-power wind turbine has higher requirements.
Shengli Guan   +5 more
openaire   +1 more source

Chemico-Physical Causes of Radiation-Induced “Long Cell” Action Corrosion in Water Cooled Reactors

18th International Conference on Nuclear Engineering: Volume 5, 2010
In the previous overview papers [1, 2], the author has identified that ‘long cell action’ corrosion plays a pivotal role in practically all unresolved corrosion issues, irrespective of reactor types and operation. In trying to confirm the existence of radiation-induced ‘long-cell’ action (macro) corrosion cell in the primary cooling system of LWRs, the
openaire   +1 more source

Steels for vessels of water-moderated water-cooled reactors of a new generation with enhanced radiation resistance

Inorganic Materials: Applied Research, 2012
A path of the formation of schools of thought on the development of high-strength vessel steels which were created by Academician of the Russian Academy of Sciences I.V. Gorynin is shown from the beginning of the 1950s to the present time. Results achieved in the field of development and application of high-strength steels for nuclear reactor vessels ...
G. P. Karzov   +2 more
openaire   +1 more source

Analysis and Computation of Characteristic of the Water Cooling and Radiating System for a Heavy Duty Truck Diesel Engine

SAE Technical Paper Series, 1993
<div class="htmlview paragraph">In this paper, on the basis of great test data, the heat exchange characteristics of the water cooling and radiating system for the Star-Steyr WD615 diesel engine series are analyzed in detail. From the characteristic of heat releasing of engine and the measured discharge curves of water pump and fan, the ...
Dehua Liu, Jinzhong Hou, Xiulan Xu
openaire   +1 more source

The Analysis of Thermal Field and Thermal Deformation of a Water-Cooling Radiator by Finite Element Simulation

2012
A water-cooling radiator is the effective heat dissipation device to ensure the high-power electrical equipment work properly and the heat transfer process and thermal deformation of the water-cooling radiator become hot research areas currently. Based on a water-cooling radiator of a company, the simulation model for its single water-cooling flow ...
Yang Lianfa, Wang Qin, Zhang Zhen
openaire   +1 more source

Thermal-Flow Coupling Simulation Analysis of Spiral Channel Water Cooled Radiator for High Power Thyristor

31st International Symposium on Ballistics, 2019
High power thyristor is the core switching device of pulse power source, which is an important component of electromagnetic launch (EML). So the reliability of high power thyristor directly affects the safe and reliable operation of EML. Semiconductor theoretical and experimental studies show that the electrical characteristics of thyristor are ...
FUQIANG MA   +5 more
openaire   +1 more source