Results 1 to 10 of about 925,626 (245)

X-ray beam monitoring and wavelength calibration using four-beam diffraction. [PDF]

open access: yesJ Synchrotron Radiat, 2022
Rigorous dynamical theory calculations show that four-beam diffraction (4BD) can be activated only by a unique photon energy and a unique incidence direction. Thus, 4BD may be used to precisely calibrate X-ray photon energies and beam positions. Based on
Huang X, Shi X, Assoufid L.
europepmc   +2 more sources

Robust Full-Screen Wavelength Calibration Algorithm

open access: yesApplied Sciences, 2023
In spectrometer measurement, it is very important to accurately calibrate the wavelength of all target characteristic spectra. Although wavelength calibration methods have long been investigated, no techniques have been designed for the scanning, double ...
Baisong Jiang   +7 more
doaj   +2 more sources

Calibration Experiments of CFOSAT Wavelength in the Southern South China Sea by Artificial Neural Networks

open access: yesRemote Sensing, 2022
The wave data measured by CFOSAT (China France Oceanography Satellite) have been validated mainly based on numerical model outputs and altimetry products on a global scale.
Junliang Liu, Shilin Tang, Junmin Li
exaly   +3 more sources

Wavelength Calibration for the LIBS Spectra of the Zhurong Mars Rover

open access: yesRemote Sensing, 2023
China’s first Mars rover, Zhurong, landed on the southern region of Utopia Planitia, Mars, on 14 May 2021 (UTC). Zhurong is equipped with the Mars Surface Composition Detection Package (MarSCoDe), which analyzes the Martian surface’s material composition.
Chunlai Li, Xin Ren, Xiangfeng Liu
exaly   +3 more sources

On-Orbit Wavelength Calibration Error Analysis of the Spaceborne Hyperspectral Greenhouse Gas Monitoring Instrument Using the Solar Fraunhofer Lines

open access: yesRemote Sensing
Accurate on-orbit wavelength calibration of the spaceborne hyperspectral payload is the key to the quantitative analysis and application of observational data.
Cailan Gong, Fuqiang Zheng
exaly   +3 more sources

Improved Wavelength Calibration by Modeling the Spectrometer [PDF]

open access: yesApplied Spectroscopy, 2022
Bryan Hennelly, Dongyue Liu
exaly   +2 more sources

Radiometric Calibration of a Dual-Wavelength, Full-Waveform Terrestrial Lidar

open access: yesSensors, 2016
Radiometric calibration of the Dual-Wavelength Echidna® Lidar (DWEL), a full-waveform terrestrial laser scanner with two simultaneously-pulsing infrared lasers at 1064 nm and 1548 nm, provides accurate dual-wavelength apparent reflectance (ρapp), a ...
Kuravi Hewawasam, Michael Schaefer
exaly   +3 more sources

ON-LINE WAVELENGTH CALIBRATION OF PULSED LASER FOR CO2 DIFFERENTIAL ABSORPTION LIDAR [PDF]

open access: yesThe International Archives of the Photogrammetry, Remote Sensing and Spatial Information Sciences, 2016
Differential absorption lidar (DIAL) remote sensing is a promising technology for atmospheric CO2 detection. However, stringent wavelength accuracy and stability are required in DIAL system.
C. Xiang   +8 more
doaj   +1 more source

Wavelength calibration of Brewer spectrophotometer using a tunable pulsed laser and implications to the Brewer ozone retrieval [PDF]

open access: yesAtmospheric Measurement Techniques, 2018
In this contribution we present the wavelength calibration of the travelling reference Brewer spectrometer of the Regional Brewer Calibration Center for Europe (RBCC-E) at PTB in Braunschweig, Germany.
A. Redondas   +11 more
doaj   +1 more source

Three-channel single-wavelength lidar depolarization calibration [PDF]

open access: yesAtmospheric Measurement Techniques, 2018
Linear depolarization measurement capabilities were added to the CANDAC Rayleigh–Mie–Raman lidar (CRL) at Eureka, Nunavut, in the Canadian High Arctic in 2010. This upgrade enables measurements of the phases (liquid versus ice) of cold and mixed-phase
E. M. McCullough   +7 more
doaj   +1 more source

Home - About - Disclaimer - Privacy