Grid Integration of Renewable Energy Sources into Weak Grids
2022This dissertation investigates the grid integration of converter-based renewable energy sources (RESs) into weak grids. For this purpose, a grid-following inverter (GFLI) is chosen as the RES, and its stability is analyzed. Additionally, the thesis proposes a method for the stability enhancement of the GFLI.
openaire +1 more source
Analysis and Enhancement of Active Power Transfer Capability for DFIG-Based WTs in Very Weak Grid
IEEE Journal of Emerging and Selected Topics in Power Electronics, 2022Wind power generation yields significant economic and social benefits, especially for developing countries. However, large wind power plants (WPPs) are usually constructed in remote areas, leading to a weak grid.
Xiang Guo +6 more
semanticscholar +1 more source
IEEE transactions on power electronics, 2022
For current-controlled grid-connected inverters with LCL filter, the essence of grid voltage full feedback is to improve the output impedance of grid-connected inverters to infinity, which can eliminate the influences of grid voltage distortion and the ...
Mingming Li, Huafeng Xiao, M. Cheng
semanticscholar +1 more source
For current-controlled grid-connected inverters with LCL filter, the essence of grid voltage full feedback is to improve the output impedance of grid-connected inverters to infinity, which can eliminate the influences of grid voltage distortion and the ...
Mingming Li, Huafeng Xiao, M. Cheng
semanticscholar +1 more source
IEEE transactions on power electronics, 2021
The feedforward schemes of the voltage at point of common coupling (PCC) have been widely used in grid-connected inverters to reject the current harmonics caused by the grid voltage distortion.
Xuehua Wang +5 more
semanticscholar +1 more source
The feedforward schemes of the voltage at point of common coupling (PCC) have been widely used in grid-connected inverters to reject the current harmonics caused by the grid voltage distortion.
Xuehua Wang +5 more
semanticscholar +1 more source
IEEE Transactions on Power Systems
Power grids located in the remote areas mostly show the features of high inverter-fed energy penetration, low grid strength, weak maintenance forces and high natural disaster risks.
Linyun Xiong +7 more
semanticscholar +1 more source
Power grids located in the remote areas mostly show the features of high inverter-fed energy penetration, low grid strength, weak maintenance forces and high natural disaster risks.
Linyun Xiong +7 more
semanticscholar +1 more source
Operating Wind Power Plants Under Weak Grid Conditions Considering Voltage Stability Constraints
IEEE transactions on power electronics, 2022This article analyzes the power transfer limit (Pmax) of wind power plants (WPPs) under the weak grid condition. It is pointed out that the impact of different grid parameters and grid configurations on Pmax cannot be fully reflected by the short-circuit
T. Lund +5 more
semanticscholar +1 more source
IEEE transactions on power electronics
This letter analyzes the transient stability of DFIG-based wind turbines (WTs) with demagnetization control during weak grid faults. It is firstly pointed out that there exist transient instability issues, and the main influential factors (i.e., fault ...
Yumei Ma +5 more
semanticscholar +1 more source
This letter analyzes the transient stability of DFIG-based wind turbines (WTs) with demagnetization control during weak grid faults. It is firstly pointed out that there exist transient instability issues, and the main influential factors (i.e., fault ...
Yumei Ma +5 more
semanticscholar +1 more source
IEEE transactions on power electronics
The classical phase-locked loop (PLL)-based vector current control scheme has been widely used in grid-following (GFL) inverter systems. However, GFL inverters with this classical control scheme tend to be unstable under severe grid fault conditions ...
Liangwei Huang, F. Blaabjerg
semanticscholar +1 more source
The classical phase-locked loop (PLL)-based vector current control scheme has been widely used in grid-following (GFL) inverter systems. However, GFL inverters with this classical control scheme tend to be unstable under severe grid fault conditions ...
Liangwei Huang, F. Blaabjerg
semanticscholar +1 more source
Stability Analysis of Grid-Connected Inverter in Weak Grid Systems
Advanced Materials Research, 2012Distributed Generation may be located far away from load centers due to their use of new energy resource distribution characteristics. In this case, Long distance transmission lines will introduce an equivalent impedance to the grid, so that the grid showing the characteristics of a weak grid.
Xin Chen, Chun Yin Gong, Lin Cheng
openaire +1 more source
IEEE Transactions on Power Systems
Modular multilevel converter-based high-voltage direct current (MMC-HVDC) systems have the potential to support grid frequency by utilizing the electrostatic energy stored in sub-module capacitors.
Haobo Zhang +3 more
semanticscholar +1 more source
Modular multilevel converter-based high-voltage direct current (MMC-HVDC) systems have the potential to support grid frequency by utilizing the electrostatic energy stored in sub-module capacitors.
Haobo Zhang +3 more
semanticscholar +1 more source