Results 301 to 310 of about 3,167,411 (345)
Some of the next articles are maybe not open access.
Connection of inverters to a weak grid
2000 IEEE 31st Annual Power Electronics Specialists Conference. Conference Proceedings (Cat. No.00CH37018), 2002Connection of an inverter to export power to the mains for a stiff supply is well understood. This paper examines the dynamics of power export to a weak grid. In this case the local bus angle changes for changes in export power which interferes with the process of synthesizing the inverter voltage.
G. Ledwich, H. Sharma
openaire +1 more source
Synchronous condenser applications for a weak grid
2023This panel session discusses the application of synchronous condensers to improve power system performance, particularly systems with a high proportion of inverter based sources. Presentations in this panel session: - Introduction to panel: Update on SynCon Interest Group Activity (23PESGM4014) - SynCon parameter study: Different transient and sub ...
K. Chen +4 more
openaire +1 more source
Wind turbines voltage support in weak grids
2013 IEEE Power & Energy Society General Meeting, 2013This paper investigates how Full-Scale Converter (FSC) wind turbines can contribute to voltage support in weak grids. A novel voltage support strategy is proposed, which optimizes the voltage support during the fault. This strategy is compared to the voltage support required by two grid codes, the Danish and the German E.ON ones.
F. Sulla, J. Svensson, O. Samuelsson
openaire +1 more source
Grid Voltage Adaptive Feed-forward Control Strategy in Weak Grid
2023 11th International Conference on Smart Grid and Clean Energy Technologies (ICSGCE), 2023Jian Wu, Xinliang Jia, Dianguo Xu
openaire +1 more source
Hardware Demonstration of Weak Grid Oscillations in Grid-Following Converters
2021 North American Power Symposium (NAPS), 2021Li Bao +3 more
openaire +1 more source
COMPARATIVE STABILITY ASSESSMENT OF GRID-FOLLOWING AND GRID-FORMING VSCS IN WEAK GRIDS
IET Conference Proceedings, 2021L. Yuan +5 more
openaire +1 more source
Modeling Type-4 Wind in Weak Grids
IEEE Transactions on Sustainable Energy, 2019An existing wind power plant at ERCOT experienced poorly damped and undamped low-frequency oscillations at $\text{3}\sim \text{4}$ Hz under weak grid condition. The objective of this paper is to shed the insight of the oscillation mechanism through linear system analysis. Two simplified models are developed and compared against a detailed model for
openaire +1 more source
IEEE transactions on industrial electronics (1982. Print), 2021
Xueguang Zhang, Meng Li, Dianguo Xu
semanticscholar +1 more source
Xueguang Zhang, Meng Li, Dianguo Xu
semanticscholar +1 more source
IEEE Transactions on Power Systems
To integrate weak onshore grids, some grid forming (GFM) control schemes taking advantage of DC voltage synchronization have been proposed for modular multilevel converter-based high-voltage direct current (MMC-HVDC) systems.
Haobo Zhang, W. Xiang, J. Wen
semanticscholar +1 more source
To integrate weak onshore grids, some grid forming (GFM) control schemes taking advantage of DC voltage synchronization have been proposed for modular multilevel converter-based high-voltage direct current (MMC-HVDC) systems.
Haobo Zhang, W. Xiang, J. Wen
semanticscholar +1 more source