Results 31 to 40 of about 798,059 (294)
INTEGRATION OF WIND FARMS INTO WEAK AC GRIDS [PDF]
Large wind farms are usually located in remote and offshore areas. High voltage transmission systems that have long transmission distances are used to deliver the wind power to main grids. Weak AC grids have high impedance, low short circuit ratio (SCR) and/or low inertia compared to strong AC grids.
openaire +1 more source
A Robust Method for Controlling Grid-Connected Inverters in Weak Grids
Stable operation of grid-connected converters with the LCL filter is essential. Variations of the grid impedance and consequently, variations of the resonance frequency, can push the system toward instability. Also, delay that comes from sampling and PWM, could worsen the stability condition.
Akhavan, Ali; id_orcid 0000-0002-9123-8844 +2 more
openaire +2 more sources
Given the problems that the phase-locked loop frequency coupling effect (PLL-FCE) in a weak grid reduces the quality of the output current waveform and brings challenges to maintaining a steady running of the grid-connected converter (GCC), this paper ...
Ye Zhang, Haibo Pen, Xiaoyu Zhang
doaj +1 more source
New power decoupling strategy for grid-connected inverter under weak power grid
This study analyzes the power coupling in a weak power grid, and designs a novel decoupling method for the coupling power with multi harmonic frequency on the dc bus.
Wai Rong-Jong, Wang Yu
doaj +1 more source
Under weak grid conditions, the variation of the grid impedance will affect the steady-state and dynamic performance of the LCL-filtered grid-connected inverter and even make the inverter unstable.
Fuyun Wu +4 more
doaj +1 more source
The Cosmological Impact of Intrinsic Alignment Model Choice for Cosmic Shear [PDF]
We consider the effect of galaxy intrinsic alignments (IAs) on dark energy constraints from weak gravitational lensing. We summarise the latest version of the linear alignment model of IAs, following the brief note of Hirata & Seljak (2010) and further ...
Anais Rassat +54 more
core +3 more sources
The stability of grid-connected wind power system (GCWPS) is prone to deteriorate due to the impedance interaction between wind turbines and the weak grid.
Haining Wang +5 more
doaj +1 more source
Control Strategy of Vienna Rectifier With LCL Filter Under Weak Grid Conditions
For the LCL type filter, there is a natural resonance peak, and the change of the grid impedance in the actual power grid will further affect the stability of the rectifier.
Yuanpeng FENG +3 more
doaj +1 more source
An assessment of the stability and performance of current controllers with harmonic compensators is presented for an inductive-capacitive-inductive (LCL)-filtered grid-connected inverter under distorted weak grid conditions.
Seung-Jin Yoon +2 more
doaj +1 more source
In a distributed generation system, the all-pass-filter phase-locked loop (APF-PLL) is a commonly used method for grid synchronization. However, the coupling effect between APF-PLL and current control loop increases the risk of oscillation instability ...
Longyue Yang +4 more
doaj +1 more source