Results 121 to 130 of about 170,606 (309)

Full‐scale Shaking Table Tests on a 10‐story Steel Moment‐resisting Frame Building with Buckling‐restrained Braces

open access: yesEarthquake Engineering &Structural Dynamics, EarlyView.
ABSTRACT In February 2023, a comprehensive series of shaking table tests were conducted at the E‐Defense facility, the world's largest three‐dimensional earthquake simulator, on a full‐scale 10‐story steel moment‐resisting frame supplemented with BRBs.
Jun Fujiwara   +9 more
wiley   +1 more source

Repeatability and Parasitic Out‐of‐Plane Motion in Controlled Rocking Structures With Cylindrical Columns: Results From Triaxial Shake Table Tests

open access: yesEarthquake Engineering &Structural Dynamics, EarlyView.
ABSTRACT Self‐centering rocking structures outperform conventional ones since they show zero post‐earthquake damage and excellent recentering; however, their applications remain limited due to concerns that rocking is extremely sensitive and nonrepeatable. This paper investigates the repeatability and parasitic out‐of‐plane motion of controlled rocking
Antonios A. Katsamakas
wiley   +1 more source

Mixing Behavior of Natural Gas and Hydrogen in a High‐Efficiency Vane (HEV) Static Mixer

open access: yesEnergy Science &Engineering, EarlyView.
Static mixers play a crucial role in the safe transport of hydrogen‐blended natural gas. Computational fluid dynamics (CFD) was employed to investigate the effects of structural parameters of the HEV static mixer on the mixing behavior and homogeneity of natural gas and hydrogen. The modeling approach was well validated against experimental data.
Xiang Zhou   +5 more
wiley   +1 more source

A Novel Bipolar DC Connection Strategy for Photovoltaic Power Plants With a 50% Reduction in DC Cabling Length

open access: yesEnergy Science &Engineering, EarlyView.
Bipolar configuration is a new topology in the direct current (DC) system of photovoltaic power plants, which is topologically analogous to the bipolar configuration utilised in High‐Voltage Direct Current power transmission systems. DC cable length and copper usage are reduced by 50% using a bipolar configuration.
Duško M. Tovilović   +2 more
wiley   +1 more source

Forced Draught Impact on Externally Venting Flames: An Experimental and Numerical Investigation

open access: yesFire and Materials, EarlyView.
ABSTRACT Wind can significantly influence fire development and spread in urban and forest environments causing fatal consequences for the public, the first responders, and the environment. Wind‐driven fires can have a significant impact on structural fires as wind can increase the fire's intensity, development, and flame spread.
Anoop Subramania Warrier   +5 more
wiley   +1 more source

Burning Lessons: The Failure to Learn From Major Fire Incidents

open access: yesFire and Materials, EarlyView.
ABSTRACT Major fire disasters continue to cause substantial loss of life, economic damage, and social disruption worldwide. Although investigations occur in most countries, lessons learned are often fragmented, published in incompatible formats, or not published at all.
Anja Hofmann‐Boellinghaus   +1 more
wiley   +1 more source

Flexibilizing inorganic thermoelectrics

open access: yesFlexMat, EarlyView.
This perspective reviews advances in flexible inorganic thermoelectric materials, covering ductile bulks, thin films, and fibers/yarns. It highlights strategies like warm metalworking, van der Waals material screening, orientation and sandwich engineering, and device integration, offering pathways to combine flexibility and performance for wearable ...
Xiao‐Lei Shi   +3 more
wiley   +1 more source

Home - About - Disclaimer - Privacy