Results 1 to 10 of about 993,052 (150)
An open GIS based 3D simulation software to predict cooling tower drift diffusion [PDF]
This paper developed XJCT-3D, a simulation software for cooling tower wet plume dispersion. By coupling it with the Open GIS component Dotspatial, we have achieved geospatial visual representation of the calculation results, which has solved the problems
Xuan Wang +5 more
doaj +2 more sources
Numerical analysis of a counter-flow wet cooling tower and its plume
A one-dimensional model to study the heat and mass transfer inside and immediately above a wet counter-flow cooling tower is described. The wet cooling tower thermodynamic model assigns zone-specific Merkel numbers to each of the rain, fill, and spray ...
A. Zargar +8 more
doaj +3 more sources
The cooling performance and water consumption of the wet cooling tower are two important parameters that must be balanced to achieve the optimum performance of this industrial component in its operating condition.
Ali Arefimanesh, Mohammad Mahdi Heyhat
doaj +3 more sources
Effect of forced ventilation on the thermal performance of wet cooling towers
To enhance the thermal performance of the wet cooling tower under crosswind environment, a 3D numerical model of a wet cooling tower is proposed based on the method of utilizing the water-dropping potential energy to achieve the purpose of forced ...
Deying Zhang +5 more
doaj +1 more source
In order to reduce the rain zone noise of wet cooling towers and enhance the heat transfer and ventilation, the effect of sound barriers on the thermal performance of wet cooling towers with synergistic optimization of fillers and water distribution was ...
BU Zhaobin +7 more
doaj +1 more source
Numerical study on water distribution of natural draft wet cooling towers under crosswind
In order to improve the thermal performance of natural draft wet cooling tower under crosswind, a three-dimensional numerical model for heat and mass transfer of cooling towers was established.
Guanghui BAI +4 more
doaj +1 more source
THEORETICAL AND EXPERIMENTAL STUDY ON THERMAL PERFORMANCE OF CLOSED WET COOLING TOWER
Thermal performance of closed wet cooling tower has been investigated experimentally and theoretically in this work. The theoretical model based on heat and mass transfer equations and heat and mass transfer balance equations which are established for ...
Najim A. Jassim
doaj +1 more source
Analysis Studying For Improving Cooling Tower [PDF]
The present investigation includes a detailed study of the proposed equation for counter flow wet cooling tower using Merkel and Poppe models to show the difference and solutions techniques of the proposed models . A mathematical model has been suggested
Sanarya k. Kamal, Saad A. Jafar
doaj +1 more source
This paper deals with the comparison of three condensation systems for the heat dissipation in a solar power plant: wet system, dry system and hybrid system based on the pre-cooling of the air in an adiabatic panel located in the entrance section of a ...
C.G. Cutillas +4 more
doaj +1 more source
Concept of CFD model of natural draft wet-cooling tower flow
The article deals with the development of CFD model of natural draft wet-cooling tower flow. The physical phenomena taking place within a natural draft wet cooling tower are described by the system of conservation law equations along with additional ...
Hyhlík T.