Results 11 to 20 of about 993,052 (150)
Sensitivity Studies of a Low Temperature Low Approach Direct Cooling Tower for Building Radiant Cooling Systems [PDF]
Recent interest in cooling towers as a mechanism for producing chilled water, together with the evolution of radiant cooling, have prompted a review of evaporative cooling in temperate maritime climates.
Nasrabadi, Mehdi +2 more
core +2 more sources
Heated moist air from a cooling tower forms a visible plume and needs to be predicted, not only for the performance design of the cooling tower, but also for environmental impact assessments.
Kazutaka Takata +2 more
doaj +1 more source
Based on the enthalpy difference theory and the characteristics of the mechanical draft cooling tower, a mathematical method of the cooling tower performance was derived to analyze the influence of operating parameters on tower outlet water temperature ...
Weimin YAO +5 more
doaj +1 more source
In view of the disadvantages of wet evaporative cooling tower such as large water evaporation, large sewage discharge, and large fog plume in winter, this paper summarized the calculation formulas of air parameters in the air-water two-phase heat and ...
Zhiming WANG +4 more
doaj +1 more source
Study of the Technologies for Freeze Protection of Cooling Towers in the Solar System
A cooling tower is an important guarantee for the proper operation of a solar system. To ensure proper operation of the system and to maintain high-efficiency points, the cooling tower must operate year-round.
Jingnan Liu +5 more
doaj +1 more source
Self-optimizing Control of Cooling Tower for Efficient Operation of Chilled Water Systems [PDF]
The chilled-water systems, mainly consisting of electric chillers and cooling towers, are crucial for the ventilating and air conditioning systems in commercial buildings. Energy efficient operation of such systems is thus important for the energy saving
Li, Xiao +3 more
core +1 more source
Analysis of Dehumidification Effects on Cooling Capacity of an Evaporative Cooler
In this study, effect of desiccant wheel, heat exchanger and cooling coil will be evaluated on decreasing the wet bulb temperature of entering air to cooling tower and decreasing the outlet cold water temperature.
Mohammad Hassan SAIDI +2 more
doaj +1 more source
Design and Operating Performance of Mechanical Draft Dry Cooling Tower Pre-cooled with Wet Medium
In order to solve the problem of insufficient output of mechanical draft dry cooling tower which can’t meet the cooling demand in summer, a mechanical draft dry cooling tower with wet medium pre-cooling inlet air system is designed in this paper.
Mingwei WANG +6 more
doaj +1 more source
The use of the Maisotsenko cycle (M-Cycle) in traditional wet cooling towers (TWCTs) has the potential to reduce the costs of electricity generation by cooling water below the inlet air’s wet-bulb temperature.
Xuchen Fan +6 more
doaj +1 more source
ObjectivesWhen distributing water across the whole tower under different water flow rates, the water distribution uniformity has a significant effect on the cooling performance of wet cooling tower.
LUO Cheng +5 more
doaj +1 more source