Results 181 to 190 of about 2,467 (241)

Novel dorsal occipito‐cervical fixation using a patient‐specific implant and drill guide for a complex craniocervical junction anomaly in a dog

open access: yesVeterinary Surgery, EarlyView.
Abstract Objective To describe a novel dorsal occipito‐cervical fixation technique utilizing a patient‐specific implant to stabilize complex craniocervical junction anomalies (CCJAs) in a small‐breed dog. Study design Case report. Animal A 7‐month‐old male Pomeranian dog.
Tae‐Wan Kwon   +4 more
wiley   +1 more source

Concept, Tests, and Optimum Design of Novel Negative Stiffness Friction Dampers for Seismic Protection of Long‐Span Bridges

open access: yesEarthquake Engineering &Structural Dynamics, Volume 55, Issue 11, Page 2719-2741, September 2026.
ABSTRACT Viscous dampers (VDs) are widely used to mitigate the excessive responses of long‐span bridges. However, VDs face some intricate challenges in engineering practices, including high damping coefficient requirement, potential base shear amplification and tremendous damping force under high velocity. To address these issues, this study develops a
Ruisheng Ma   +5 more
wiley   +1 more source

The Theory of Critical Distances for Predicting the Static Failure of Double‐Lap Bolted Joints With Conventional and Additively Manufactured 316L Stainless Steel Inner Plates

open access: yesFatigue &Fracture of Engineering Materials &Structures, Volume 49, Issue 9, Page 3831-3853, September 2026.
ABSTRACT This study assesses the accuracy of the theory of critical distances applied in the form of the point method in predicting the static strength of 316L stainless steel double‐lap shear bolted connections under static tensile loading. Single‐ and double‐bolt configurations were tested using inner plates manufactured from conventional material ...
Hasan Almuhanna   +2 more
wiley   +1 more source

Clinical implementation and performance evaluation of a motorized MR‐compatible OCTAVIUS 4D system for SBRT patient‐specific QA on a 1.5 T MR‐LINAC

open access: yesJournal of Applied Clinical Medical Physics, Volume 27, Issue 8, August 2026.
Abstract Background Magnetic resonance–guided radiotherapy using 1.5 T MR‐LINAC systems introduces specific constraints for patient‐specific quality assurance (PSQA), requiring MR‐compatible dosimetric devices capable of accurate three‐dimensional dose verification.
Clement Chevillard   +5 more
wiley   +1 more source

An Embodied Paper‐Based Microfluidic Al‐Air Battery for Enduring Untethered Insect‐Scale Robots

open access: yesAdvanced Science, Volume 13, Issue 45, 13 August 2026.
This work presents a centimeter‐scale microfluidic aluminum–air battery (MFAAB) with dual‐surface anode and F−‐mediated byproduct decomposition. The design enables a high capacity of 2697.05 mAh/g Al and delivers tens of milliwatts to power LEDs, motors, and a toy car.
Yun Yang   +5 more
wiley   +1 more source

Home - About - Disclaimer - Privacy