Results 131 to 140 of about 2,841,431 (249)
X-ray Emission from Elliptical Galaxies [PDF]
Elliptical galaxies are generally luminous sources of X-ray radiation, and contain large amounts of hot, interstellar gas. In the brighter X-ray galaxies, the inferred masses of hot gas are consistent with those expected given the present rates of stellar mass loss.
arxiv
Abstract Skin flash is typically added to breast and chestwall plans to ensure robust target coverage in the presence of respiratory motion, anatomic changes, and small setup uncertainties. Adding skin flash in volumetric modulated arc therapy (VMAT) plans is an iterative and manual process.
Emily Hubley+6 more
wiley +1 more source
The crucial discovery of thermonuclear X-ray bursts: never throw away old data! [PDF]
The detection of Type I X-ray bursts is attributed to those seen by the Astronomical Netherlands Satellite (ANS) in September 1975 from the globular cluster NGC6624 containing the X-ray source 4U1820-303. I revisit these X-ray bursts, by re-analysing data from the Soft X-ray Experiment (SXX) onboard ANS, which were stored on microfiche.
arxiv
Abstract Purpose/objectives Recent technological advancements have increased efficiency for clinical deliverability of online‐adaptive‐radiotherapy (oART). Previous cone‐beam‐computed‐tomography (CBCT) generations lacked the ability to provide reliable Hounsfield‐units (HU), thus requiring oART workflows to rely on synthetic‐CT (sCT) images derived ...
Jingwei Duan+7 more
wiley +1 more source
Abstract Purpose Single‐isocenter multitarget (SIMT) radiosurgery has become increasingly popular as advancement in planning and delivery systems have made this approach clinically viable. With targets varying in size and distance from isocenter, SIMT plans are highly complex with dynamic multileaf collimator (MLC) motion.
Hem Moktan+3 more
wiley +1 more source
Abstract Purpose Palliative radiotherapy comprises a significant portion of the radiation treatment workload. Volumetric‐modulated arc therapy (VMAT) improves dose conformity and, in conjunction with flattening filter free (FFF) delivery, can decrease treatment times, both of which are desirable in a population with a high probability of retreatment ...
Madeleine L. Van de Kleut+2 more
wiley +1 more source
Evaluation of the effect of metal stents on dose perturbation in the carbon beam irradiation field
Abstract Propose Carbon ion therapy is indicated for cases in which stents have been inserted, such as bile ducts, but the effect of metal stents on carbon ion therapy is unclear. In this study, the dose perturbation of carbon ion therapy caused by metallic bile duct stents was evaluated by dosimetry. Materials and methods Five different types of metal
Yuya Miyasaka+8 more
wiley +1 more source
Abstract This study evaluates various radiotherapy techniques for treating metastatic brain tumor (BT), focusing on non‐coplanar volumetric modulated arc radiotherapy (NC‐VMAT), coplanar VMAT (C‐VMAT), Helical TomoTherapy (HT), CyberKnife (CK), Gamma Knife (GK), and ZAP‐X.
Toshihiro Suzuki+9 more
wiley +1 more source
3D imaging of magnetic domains in Nd2Fe14B using scanning hard X-ray nanotomography
Nanoscale structural and electronic heterogeneities are prevalent in condensed matter physics. Investigating these heterogeneities in 3D has become an important task for understanding material properties.
Srutarshi Banerjee+7 more
doaj +1 more source
X-Ray Flashes on Helium Novae [PDF]
A helium nova occurs on a white dwarf (WD) accreting hydrogen-deficient matter from a helium star companion. When the mass of a helium envelope on the WD reaches a critical value, unstable helium burning ignites to trigger a nova outburst. A bright soft X-ray phase appears in an early outbursting phase of a helium nova before it optically rises toward ...
arxiv