Results 81 to 90 of about 10,368 (249)

Intermediate Resistive State in Wafer‐Scale Vertical MoS2 Memristors Through Lateral Silver Filament Growth for Artificial Synapse Applications

open access: yesAdvanced Functional Materials, EarlyView.
In MOCVD MoS2 memristors, a current compliance‐regulated Ag filament mechanism is revealed. The filament ruptures spontaneously during volatile switching, while subsequent growth proceeds vertically through the MoS2 layers and then laterally along the van der Waals gaps during nonvolatile switching.
Yuan Fa   +19 more
wiley   +1 more source

Two-bunch seeding of soft x-ray free electron lasers

open access: yesPhysical Review Accelerators and Beams
Seeded free electron lasers (FELs) demonstrate a good performance and are successfully used in different user experiments in extreme ultraviolet and soft x-ray regimes.
E. Schneidmiller, I. Zagorodnov
doaj   +1 more source

Integration of Low‐Voltage Nanoscale MoS2 Memristors on CMOS Microchips

open access: yesAdvanced Functional Materials, EarlyView.
This article presents the first monolithic integration of nanoscale MoS2‐based memristors into the back‐end‐of‐line of foundry‐fabricated CMOS microchips in a one‐transistor‐one‐resistor (1T1R) architecture. The MoS2‐based 1T1R cells exhibit forming‐free, nonvolatile resistive switching with ultra‐low operating voltages, low cycle‐to‐cycle variability ...
Jimin Lee   +16 more
wiley   +1 more source

Strain‐Programmable Luminescent Adhesive Patch With Tartrazine‐Mediated Optical Skin Clearing for Photochemical Tissue Bonding

open access: yesAdvanced Functional Materials, EarlyView.
We propose a suture‐complementary approach that integrates optical skin clearing with a strain‐programmable luminescent adhesive patch. Hyaluronic acid promotes transdermal delivery of tartrazine to improve optical clearing and stabilizes its interaction with a photosensitizer. Optical clearing increases the penetration depth of visible light into skin,
Seong‐Jong Kim   +6 more
wiley   +1 more source

Receptor‐Free Identification of Toxic Gases Enabled by Hygroscopic Aqueous Salt Films

open access: yesAdvanced Functional Materials, EarlyView.
Water as a gas sensor coating sounds impossible—until it stops evaporating. Here, hygroscopic salt solutions (LiCl, LiBr, H3PO4) form non‐drying aqueous films on CNT chemiresistors under ambient air. Gases partition into these liquid layers, sometimes transforming into water, and generate salt‐specific resistance fingerprints across a four‐channel ...
Seongwoo Lee   +5 more
wiley   +1 more source

Development of portable nanofocusing optics for X-ray free-electron laser pulses

open access: yesJournal of Synchrotron Radiation
We present the development of a portable and compact nanofocusing system utilizing Kirkpatrick–Baez optics for X-ray free-electron lasers (XFELs). The system has a total length of merely 340 mm from the initial elliptical mirror to the focal point.
Yuichi Inubushi   +8 more
doaj   +1 more source

Method for polarization shaping at free-electron lasers

open access: yesPhysical Review Accelerators and Beams, 2019
X-ray free electron lasers provide short, polarized, high-power pulses of x-ray radiation, where polarization properties are determined by the undulator magnetic field.
Svitozar Serkez   +3 more
doaj   +1 more source

Irradiation‐Induced Spin Bath Evolution and as‐Grown Hydrogen Defects in CVD Diamond Revealed by NV‐Based DEER Spectroscopy

open access: yesAdvanced Functional Materials, EarlyView.
Here, we provide the reader with the current state of the art in the fabrication of high‐T2‐coherence diamond, optimized through the use of double electron–electron resonance (DEER) spectroscopy. We reveal the main as well as yet unidentified spin defects, the reduction of which is essential for reducing the spin bath and fabricating materials for ...
Olga Rubinas   +6 more
wiley   +1 more source

Chemical State Detection and Charge Transfer in Complex Oxide Heterostructures via In Situ Auger Electron Spectroscopy

open access: yesAdvanced Functional Materials, EarlyView.
In situ Auger Electron Spectroscopy resolves oxidation states with high fidelity during the pulsed laser deposition of multivalent perovskite manganate and vanadate heterostructures. The chemical‐state signature is carried by the valence‐electron population of the transition‐metal cation, read out through the relative intensities of Auger fine ...
Harish Kumarasubramanian   +1 more
wiley   +1 more source

Signal extraction in SWAXS data for the compact X-ray light sources: a machine learning approach

open access: yesScientific Reports
The development of X-ray free electron lasers has driven significant progress in X-ray science. Given the broad range of their applications, implementing a new generation of this technology at the laboratory scale has been under consideration for several
Adam K. Opperman   +8 more
doaj   +1 more source

Home - About - Disclaimer - Privacy