Results 151 to 160 of about 7,531,616 (402)
The recent progress in the measurement and understanding of the X-ray background is reviewd here. Particular emphasis is put on a discussion of the partially discrepant measurement of the X-ray background spectrum in the 0.5-3 keV range. New and important constraints on large scale structure are obtained from measurements of the smoothness of the XRB ...
openaire +4 more sources
Abstract Purpose To compare plan quality among photon volumetric modulated arc therapy (VMAT) and intensity‐modulated proton therapy (IMPT) with robustness using three different proton beam delivery systems with various spot size (σ) ranges: cyclotron‐generated proton beams (CPBs) (σ: 2.7–7.0 mm), linear accelerator proton beams (LPBs) (σ: 2.9–5.5 mm),
Tara Gray+9 more
wiley +1 more source
RELATION BETWEEN BACTEREMIA AND DEATH IN MICE FOLLOWING X-RAY AND THERMAL COLUMN EXPOSURES [PDF]
Irene U. Boone+2 more
openalex +1 more source
The effect of multi‐leaf collimator leaf width on VMAT treatment plan quality
Abstract Background The advent of volumetric modulated arc therapy (VMAT) in radiotherapy has made it one of the most commonly used techniques in clinical practice. VMAT is the delivery of intensity modulated radiation therapy (IMRT) while the gantry is in motion, and existing literature has shown it has decreased treatment delivery times and the ...
Gregory Sadharanu Peiris+3 more
wiley +1 more source
ELIMINATION OF ERRORS IN THE X RAY DIAGNOSIS OF URINARY CALCULUS. [PDF]
EdwardW.H. Shenton
openalex +1 more source
Abstract Purpose Quantify the impact of additional imaging doses on clinical dose constraints during lung stereotactic body radiotherapy (SBRT) treatment utilizing stereoscopic/monoscopic real‐time tumor monitoring. Materials and Methods Thirty lung SBRT patients treated with the volumetric arc therapy technique were randomly selected from the ...
Ruwan Abeywardhana, Mike Sattarivand
wiley +1 more source
High energy X-rays (115.56 keV) were used to measure the HIPed interface of F82H steel. The X-ray energy spectra of the samples were analyzed focusing on W and Ta fluorescence X-rays, Compton scattering and elastic scattering X-rays.
Hiroshi Sakurai+11 more
doaj
Abstract Purpose Cardiac motion may degrade dose distribution during stereotactic arrhythmia radioablation using the CyberKnife system, a robotic radiosurgery system. This study evaluated the dose distribution changes using a self‐made cardiac dynamic platform that mimics cardiac motion. Methods The cardiac dynamic platform was operated with amplitudes
Takayuki Miyachi+6 more
wiley +1 more source
Treatment of Murine Leukaemia with X Rays and Homologous Bone Marrow [PDF]
David W. Barnes+3 more
openalex +1 more source
Abstract This study aimed to evaluate the dose‐exposure reduction effect of a crystalline lens with a bismuth eye shield using cone‐beam computed tomography (CBCT) for head image‐guided radiation therapy. The ocular surface dose of the head phantom (THRA‐1) is defined as a crystalline lens exposure dose and is measured using a radiophotoluminescence ...
Tatsuya Yoshida+5 more
wiley +1 more source