Results 201 to 210 of about 3,689 (252)
Unveiling the role of local temperature gradients in individual zeolites containing metal active sites. [PDF]
Zhao B +10 more
europepmc +1 more source
Solid-solution surface alloying of Cu nanocubes with platinum-group metals: pathway switching and catalyst stabilization in CO<sub>2</sub> reduction. [PDF]
Kobayashi H +15 more
europepmc +1 more source
MgO/NiCoFe<sub>2</sub>O<sub>4</sub> modified electrochemical sensor for simultaneous detection of ascorbic acid and levofloxacin. [PDF]
Chandio IG +8 more
europepmc +1 more source
Specific construction of asymmetric carbon-nickel-chlorine single-atom sites via carbon vacancy engineering for efficient CO<sub>2</sub> electroreduction. [PDF]
Hao Q +5 more
europepmc +1 more source
Some of the next articles are maybe not open access.
Related searches:
Related searches:
Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 2005
We report the results of the intermediate valence compound EuCu2Si2 local electron and crystalline structure studies by means of L3-Eu XANES and K-Cu EXAFS spectroscopy. Temperature dependence of the europium valence has been defined. In EXAFS studies, we have analyzed Cu atoms local environment and have revealed bond length and rigidity parameters of ...
Alekseev, P. A. +4 more
openaire +2 more sources
We report the results of the intermediate valence compound EuCu2Si2 local electron and crystalline structure studies by means of L3-Eu XANES and K-Cu EXAFS spectroscopy. Temperature dependence of the europium valence has been defined. In EXAFS studies, we have analyzed Cu atoms local environment and have revealed bond length and rigidity parameters of ...
Alekseev, P. A. +4 more
openaire +2 more sources
Molecular Dynamics Simulations and XAFS (MD-XAFS)
2016MD-XAFS (Molecular Dynamics X-ray Adsorption Fine Structure) makes the connection between simulation techniques that generate an ensemble of molecular configurations and the direct signal observed from X-ray measurement. Due to the fact that the signal is most sensitive to the structure nearest to a photoelectron source, an understanding of XAFS signal
Gregory K. Schenter, John L. Fulton
openaire +1 more source
Physica B: Condensed Matter, 1995
Abstract We present an X-ray absorption study of zinc selenide at the Zn and Se K-edges. The analysis of the X-ray absorption fine structure (XAFS) was done in the framework of the multiple-scattering theory. The total XAFS signals have been obtained; they are in good agreement with the experimental data.
D. Diop, R. Grisenti
openaire +1 more source
Abstract We present an X-ray absorption study of zinc selenide at the Zn and Se K-edges. The analysis of the X-ray absorption fine structure (XAFS) was done in the framework of the multiple-scattering theory. The total XAFS signals have been obtained; they are in good agreement with the experimental data.
D. Diop, R. Grisenti
openaire +1 more source
XAFS in dilute magnetic semiconductors
Dalton Transactions, 2013X-Ray absorption fine structure (XAFS) spectroscopy has experienced a rapid development in the last four decades and has proved to be a powerful structure characterization technique in the study of local environments in condensed matter. In this article, we first introduce the XAFS basic principles including theory, data analysis and experiment in some
Zhihu, Sun +5 more
openaire +2 more sources
Physica B: Condensed Matter, 1989
Abstract The transferability concept is central to all practical applications of XAFS for structure determination, both experimental and theoretical. In this paper the question of transferability in EXAFS is re-examines. Physical arguments ndicate that transferability is much less accurate for multiple scattering than for single scattering. Therefore
openaire +1 more source
Abstract The transferability concept is central to all practical applications of XAFS for structure determination, both experimental and theoretical. In this paper the question of transferability in EXAFS is re-examines. Physical arguments ndicate that transferability is much less accurate for multiple scattering than for single scattering. Therefore
openaire +1 more source

