Results 91 to 100 of about 14,865 (237)
We demonstrate experimentally Hanbury Brown and Twiss (HBT) interferometry at a hard X-ray Free Electron Laser (XFEL) on a sample diffraction patterns.
Chollet, M. +15 more
core
This work demonstrates that multi‐position data acquisition mitigates radiation damage in electron diffraction of three‐dimensional protein crystals and that merging data from selected crystals in distinct orientations enhances completeness. Application of the two approaches enables high‐quality structural models to be obtained from limited or ...
Alaa Shaikhqasem +8 more
wiley +1 more source
Cylindrical compression of thin wires by irradiation with a Joule-class short-pulse laser
Equation of state measurements at Jovian or stellar conditions are currently conducted by dynamic shock compression driven by multi-kilojoule multi-beam nanosecond-duration lasers.
Alejandro Laso Garcia +17 more
doaj +1 more source
Diamond sensors for hard X-ray energy and position resolving measurements at the European XFEL
The diagnostics of X-ray beam properties has a critical importance at the European X-ray Free-Electron Laser facility. Besides existing diagnostic components, utilization of a diamond sensor was proposed to achieve radiation-hard, non-invasive beam ...
Tuba Çonka Yıldız +7 more
doaj +1 more source
Heterogeneous multireference alignment: a single pass approach
Multireference alignment (MRA) is the problem of estimating a signal from many noisy and cyclically shifted copies of itself. In this paper, we consider an extension called heterogeneous MRA, where $K$ signals must be estimated, and each observation ...
Bendory, Tamir +3 more
core +1 more source
Hard X-ray operation of X-ray gas monitors at the European XFEL
X-ray gas monitors (XGMs) are operated at the European XFEL for non-invasive single-shot pulse energy measurements and average beam-position monitoring.
Theophilos Maltezopoulos +10 more
doaj +1 more source
Future Circular Collider Week 2017, FCC Week 2017, Berlin, DESY, Germany, 29 May 2017 - 2 Jun ...
Weise, Hans, Decking, Winfried
openaire +2 more sources
Calculation of effective pump dose in X-ray-pump/X-ray-probe experiments
In pump–probe experiments on solid materials performed within ultrafast X-ray science, the energy deposited by an X-ray pump pulse in the sample has a non-uniform spatial distribution.
Sebastião Antunes +6 more
doaj +1 more source
Output characteristics of the European XFEL have been previously studied assuming an operation point at 5 kA peak current. In this paper we explore the possibility to go well beyond such nominal peak current level. In order to illustrate the potential of
Geloni, Gianluca +4 more
core
RADDOSE-XFEL: femtosecond time-resolved dose estimates for macromolecular XFEL experiments
For macromolecular structure determination at synchrotron sources, radiation damage remains a major limiting factor. Estimation of the absorbed dose (J kg−1) during data collection at these sources by programs such as RADDOSE‐3D has allowed direct comparison of radiation damage between experiments carried out with different samples and beam parameters.
Dickerson, JL, McCubbin, PTN, Garman, EF
openaire +1 more source

