Results 51 to 60 of about 139,328 (210)

Influence of the Cable Accessories Installing Method on the Partial Discharge Activity in Medium Voltage Cables

open access: yesEnergies, 2022
This article proposes a method to modify the construction of a medium voltage (MV) heat shrinkable cable termination in cases of atypical damage to the shields of cross-linked polyethylene (XLPE) insulated cables.
Jacek Rybarz   +4 more
doaj   +1 more source

Melt Grafting of Geometry‐Tailored Voltage Stabilizers for High‐Performance Polypropylene Insulation

open access: yesAdvanced Functional Materials, Volume 36, Issue 30, 13 April 2026.
A scalable one‐step melt grafting strategy is developed to enhance the dielectric properties of isotactic polypropylene by covalently incorporating thermally stable aromatic voltage stabilizers. This solvent‐free approach improves volume resistivity and DC breakdown strength through deep trap formation and charge localization, offering a sustainable ...
Nazirul Mubin bin Normansah   +9 more
wiley   +1 more source

Environmental moisture ingress characteristics in high-voltage cable port assemblies: Temperature-humidity coupling effects analysis

open access: yesResults in Engineering
As the field of storage cables is yet to mature in sealing devices and methods, the ports of such cables are poorly sealed. This causes environmental moisture to intrude from the ports, rendering the cable ports damp. In order to investigate the moisture
Sichen Qin   +4 more
doaj   +1 more source

Evaluation of Moisture Ageing Status of Cross‐Linked Polyethylene Insulation in Power Cables at Different Temperatures

open access: yesHigh Voltage, Volume 11, Issue 2, Page 410-420, April 2026.
ABSTRACT Cross‐linked polyethylene (XLPE) cables play an important role in power systems to transport electrical energy, and moisture is one of the important predisposing factors for insulation failure in medium and high‐voltage cables. In this paper, a temperature‐moisture accelerated ageing experiment is designed, and a method for assessing the ...
Wen Luo   +7 more
wiley   +1 more source

Space charge determination in HVDC power cable and its influence on electric field

open access: yes, 2010
Considerable amount of transmission and distribution of electricity is carried out by power cable. At present, most high voltage direct current (HVDC) installation uses traditional (oil-impregnated paper insulation and oil-filled-types) cables which pose
Choo, Chin Tze
core   +1 more source

Multiterminal High‐Voltage Direct Current Projects: A Comprehensive Assessment and Future Prospects

open access: yesHigh Voltage, Volume 11, Issue 2, Page 317-344, April 2026.
ABSTRACT Multiterminal high‐voltage direct current (MT‐HVDC) systems are an important part of modern power systems, addressing the need for bulk power delivery and efficient renewable energy integration. This paper provides a comprehensive overview of recent advances in MT‐HVDC technology, including launched projects and ongoing initiatives.
Mohammad Hossein Mousavi   +3 more
wiley   +1 more source

Electrical Treeing Characteristics in XLPE Power Cable Insulation in Frequency Range between 20 and 500 Hz

open access: yes, 2009
Electrical treeing is one of the main reasons for long term degradation of polymeric materials used in high voltage ac applications. In this paper we report on an investigation of electrical tree growth characteristics in XLPE samples from a commercial ...
Tham, C H, Chen, George
core   +1 more source

Hawaii Deep Water Cable Program phase II : cable construction specification [PDF]

open access: yes, 1985
This document constitutes a detailed construction specification covering the design, fabrication and testing of the preferred 250 MW dc self contained oil filled (SCOF) cable to be used for the laboratory and possibly at-sea portions of the U.S ...
Pirelli Cable Corporation
core   +2 more sources

Time‐Domain Computation of Propagation Characteristics of Partial Discharge in Cross‐Linked Polyethylene High‐Voltage Cable Incorporating Modified Frequency‐Dependent Parameters

open access: yesHigh Voltage, Volume 11, Issue 2, Page 421-433, April 2026.
ABSTRACT The propagation characteristics of partial discharge (PD) in cables impact PD detection sensitivity, defect localisation accuracy and defect severity evaluation. Currently, the effects of semiconducting materials' frequency‐dependent properties and corrugated aluminium sheath structures on PD signal propagation in high‐voltage (HV) cables ...
Weisheng He   +6 more
wiley   +1 more source

Effects of Exposure to Radiation and Steam on Silicone Rubber Cables Removed From a Nuclear Power Plant

open access: yesHigh Voltage, Volume 11, Issue 2, Page 482-493, April 2026.
ABSTRACT Low‐voltage cables insulated with silicone rubber were harvested from three locations in the primary containment vessel of a boiling water nuclear power plant (NPP). Subsequently, the cable, which was placed in an ambient environment with a relatively higher temperature and the highest rate, was cut into four shorter ones.
Yoshimichi Ohki   +2 more
wiley   +1 more source