Results 61 to 70 of about 139,328 (210)
To enhance the application of ultra-low frequency dielectric loss testing technology in evaluating cable insulation conditions and to improve the testing efficiency of ultra-low frequency dielectric spectroscopy, the dielectric properties of cross-linked
Haiyu SUN +5 more
doaj +1 more source
The impact of XLPE surface defects on electric field and breakdown voltage
During the construction of cable joints, three common defects may occur on the XLPE surface: scratches, moisture exposure, and adhered contaminated particles.
Guanghua He +6 more
doaj +1 more source
The conduction characteristics of electrical trees in XLPE cable insulation [PDF]
AbstractDepending on the morphology of the material and applied voltage frequency, three kinds of electrical trees can exist in cross‐linked polyethylene (XLPE) cable insulation, which are conducting, non‐conducting, and mixed trees with different growth mechanisms.
Xie, Ansheng +3 more
openaire +1 more source
The effects of material modification and cross-linking by-products (residues) quantity on space charge accumulation and decay in XLPE have been investigated using the pulsed electro-acoustic technique.
Fothergill, J C +3 more
core +1 more source
Nondestructive Detection of Thermal Aging in XLPE Based on Terahertz Spectroscopy
XLPE power cables have become the core insulation material in the power cable industry and are widely used in high-voltage and extra-high-voltage cable systems due to their advantages of large transmission capacity, excellent dielectric properties, and ...
Junping Cao +8 more
doaj +1 more source
ABSTRACT Maleic anhydride (MAH) grafting modification is an effective approach to enhance the insulating performance of polyethylene (PE) cable insulations. However, the high polarity of MAH often causes considerable dielectric loss, making it unsuitable for AC systems.
Shixun Hu +12 more
wiley +1 more source
Understanding the Mechanism of Junction Effect of Homo‐Bilayer XLPE for HVDC Cable Factory Joints
In high‐voltage direct current cable systems, the factory joint of cross‐linked polyethylene (XLPE)‐insulated cables presents significant electrical breakdown risk. The charge accumulation mechanism at the XLPE–XLPE interface involves the accumulation of
Xiaofan Song +6 more
doaj +1 more source
The combined insulation interface of a high-voltage cable and accessories is the weakest part of a cable system. In this paper, the parameters of the dielectric constant, thermal conductivity, and elastic modulus of cross-linked polyethylene (XLPE) and ...
Xu Lu +6 more
doaj +1 more source
Simulation and partial discharge detection for typical defects of 10 kV cable the joint
In order to explore the partial discharge characteristics of 10 kV XLPE insulated cable (hereinafter referred to as ‘XLPE cable’), first six typical defects are made on the main insulation according to the requirements of the installation process and the
Yunfeng Xia +4 more
doaj +1 more source
ABSTRACT Silicone rubber (SR), an organic silicon polymer material, is known for its excellent heat resistance and mechanical properties. It is widely used in composite insulators and cable accessory materials. However, the ageing caused by humidity and heat significantly impacts its performance, an issue that cannot be ignored. This paper investigates
Wenyu Ye +6 more
wiley +1 more source