IEEE Transactions on Applied Superconductivity, 2014
A 500 kV saturated iron-core superconductive fault current limiter (SISFCL) has been designed to be installed in an extra high voltage (EHV) transmission system in southern China. We carried out studies on compatibility and coordination problems in the application of this kind of device in an EHV network.
null Bin Li +5 more
openaire +1 more source
A 500 kV saturated iron-core superconductive fault current limiter (SISFCL) has been designed to be installed in an extra high voltage (EHV) transmission system in southern China. We carried out studies on compatibility and coordination problems in the application of this kind of device in an EHV network.
null Bin Li +5 more
openaire +1 more source
IEEE transactions on industrial electronics (1982. Print), 2020
Open-winding permanent magnet synchronous machines (OW-PMSMs) with a common dc bus have gained increasing research focus in recent years due to its advantages including multilevel modulation and flexible control capability.
Zhanfeng Song, Siyu Hu, Ran Zhang
semanticscholar +1 more source
Open-winding permanent magnet synchronous machines (OW-PMSMs) with a common dc bus have gained increasing research focus in recent years due to its advantages including multilevel modulation and flexible control capability.
Zhanfeng Song, Siyu Hu, Ran Zhang
semanticscholar +1 more source
IEEE transactions on industrial electronics (1982. Print), 2019
Zero-sequence current (ZSC) is inevitable in the structure of an open-end winding permanent-magnet synchronous machine (OW-PMSM) system with a common dc bus due to the simultaneous existence of the ZSC loop and the zero-sequence voltage (ZSV) caused by ...
Wei Hu, H. Nian, Dan Sun
semanticscholar +1 more source
Zero-sequence current (ZSC) is inevitable in the structure of an open-end winding permanent-magnet synchronous machine (OW-PMSM) system with a common dc bus due to the simultaneous existence of the ZSC loop and the zero-sequence voltage (ZSV) caused by ...
Wei Hu, H. Nian, Dan Sun
semanticscholar +1 more source
IEEE International Conference on Applied Superconductivity and Electromagnetic Devices, 2020
The open-winding topology with common dc bus is applied to permanent magnet brushless motor for promoting power density and elevating torque output capacity, however zero-sequence current will be generated in the winding which would reduce the efficiency
Qing Lu, Yeqin Wang, Xiaoting Ye
semanticscholar +1 more source
The open-winding topology with common dc bus is applied to permanent magnet brushless motor for promoting power density and elevating torque output capacity, however zero-sequence current will be generated in the winding which would reduce the efficiency
Qing Lu, Yeqin Wang, Xiaoting Ye
semanticscholar +1 more source
Circulating zero-sequence current control of parallel three-phase inverters
IEE Proceedings - Electric Power Applications, 2006A novel circulating zero-sequence current-control method for common DC-source parallel inverter systems is proposed and implemented in FPGA. The follower inverter can closely track the three-phase discontinuous PWM modulation waveforms of the master inverter and the circulating current caused by asynchronous modulation waveforms can be reduced.
openaire +1 more source
2020 5th International Conference on Smart Grid and Electrical Automation (ICSGEA), 2020
When the high-impedance grounding fault (HIGF) occurs in the resonant grounding system, the fault current is weak, and the traditional relay protection device cannot identify and remove the fault reliably.
Jiran Zhu +4 more
semanticscholar +1 more source
When the high-impedance grounding fault (HIGF) occurs in the resonant grounding system, the fault current is weak, and the traditional relay protection device cannot identify and remove the fault reliably.
Jiran Zhu +4 more
semanticscholar +1 more source
A Review of System Grounding Methods and Zero Sequence Current Sources
2008 61st Annual Conference for Protective Relay Engineers, 2008The purpose of this paper is to provide a tutorial or "refresher" on grounding methods, sources of ground current, ground current flow in the power system, and how each impacts protective relaying. With retirements, new hires, reorganization, cross training, and so on, this subject, like many others, requires regular review to maintain the experience ...
Gerald Johnson +2 more
openaire +1 more source
Insulation Deterioration Detection by Zero-Sequence Current Analysis for Induction Motors
IEEJ Transactions on Industry Applications, 2011Insulation tests for the stator coil, which decides the motor life, are carried out once several years in power and industrial plant. In the case of high voltage (HV) motors, insulation failure may adversely affect plant operation. Hence, maintenance activities, including insulation tests, research on insulation deterioration, and online Partial ...
Hideki Iwanaga, Hiroshi Inujima
openaire +1 more source
IEEE transactions on power electronics, 2019
Owing to high driving power, good controllability, and strong fault-tolerant ability, a three-phase open-end winding permanent magnet synchronous motor driven by a dual inverter with common dc bus is considered as a competitive solution.
Xiaogang Lin, Wenxin Huang, Le Wang
semanticscholar +1 more source
Owing to high driving power, good controllability, and strong fault-tolerant ability, a three-phase open-end winding permanent magnet synchronous motor driven by a dual inverter with common dc bus is considered as a competitive solution.
Xiaogang Lin, Wenxin Huang, Le Wang
semanticscholar +1 more source