Results 1 to 10 of about 501,025 (149)

Knowledge and attitudes about the use of pangolin scale products in Traditional Chinese Medicine (TCM) within China

open access: yesPeople and Nature, Volume 2, Issue 4, Page 903-912, December 2020., 2020
Abstract All eight pangolin species are threatened with extinction, largely through demand for their products including scales, meat and body parts. The demand for pangolin scales has gained attention from many conservation groups due to the large volumes involved in illegal trade.
Yifu Wang   +3 more
wiley   +1 more source

International clinical practice recommendations on the definition, diagnosis, assessment, intervention, and psychosocial aspects of developmental coordination disorder – Chinese (Mandarin) translation

open access: yesDevelopmental Medicine &Child Neurology, Volume 61, Issue 3, Page E1-E35, March 2019., 2019
目的 本国际临床指南由欧洲残疾儿童学会(the European Academy of Childhood Disability,EACD)牵头制定,旨在解决发育性协调障碍(developmental coordination disorder,DCD)的定义、诊断、评估、干预以及与社会心理方面的临床应用关键问题。 方法 本指南针对五个领域的关键问题,通过文献综述和专家团队的正式讨论达成共识。为保证指南的循证基础,以“机制”、“评估”和“干预”为检索词, 对2012年更新以来提出的最新建议以及新增的“社会心理问题”和“青少年/成人”为检索词进行检索。根据牛津大学循证医学中心证据等级 (证据水平 [level of evidence, LOE]1–4) 将结果进行分类,最终转化为指南建议。并由国际 ...
Jing Hua   +6 more
wiley   +1 more source

110 kV并联电容器装置分闸重击穿时避雷器吸收能量研究

open access: yesDianci bileiqi, 2021
110 kV并联电容器装置具有单组容量大、电压等级高的特点,而其结构形式和运行工况又与传统并联电容器装置有所区别,因此研究其避雷器参数合理选取原则对于提高其经济性和安全可靠性具有重要意义。以特高压工程110 kV/240 MVA并联电容器装置为研究对象,对其正常分闸重击穿以及单相接地故障情况下单相重击穿时出现的过电压水平进行了理论分析,并在此基础上建立了避雷器吸收能量仿真模型,仿真分析了各种重击穿情况下避雷器的吸收能量以及运行工况对避雷系吸收能量的影响规律,最终提出了最严重工况下避雷器吸收能量的选取建议:
何慧雯, 尹婷, 马跃, 王子建
doaj  

气体火花间隙开关的自击穿性能研究

open access: yesGaoya dianqi, 2021
为了解气体火花间隙开关的自击穿性能,文中从自击穿实验角度着手,对电场不均匀度进行了仿真计算,测量了两电极气体火花间隙开关不同间隙距离下的自击穿电压,通过计算相对极差和变异系数来分析自击穿电压的稳定性并进行韦布尔检验。实验结果表明,自击穿电压随间隙距离的增大而增大并近似线性关系;间隙距离是影响自击穿电压稳定性的重要因素,自击穿电压的稳定性随间隙距离的增大而增大。从自击穿稳定性角度来看,可以适当增大气体火花间隙开关的电极之间间隙距离来增强自击穿电压稳定性。
满林坤   +5 more
doaj  

Tantalum‐Driven Interfacial Reconstruction Enables Ultra‐Low Contact Resistance in TiAlTa/Au GaN HEMTs

open access: yesRare Metals, Volume 45, Issue 2, February 2026.
ABSTRACT The transformative potential of gallium nitride high electron mobility transistors (GaN HEMTs) in advancing carbon‐neutral power systems remains bottlenecked by contact resistance (Rc) at the metal–semiconductor (M‐S) interface, a critical determinant of switching losses and frequency response.
Ji‐Zhou Zhang   +8 more
wiley   +1 more source

From Microstructure to Macroscopic Performance: A Comprehensive Study on Low‐K Oxide‐Doped BNT–LST–NN Ceramics for Energy Storage

open access: yesRare Metals, Volume 45, Issue 2, February 2026.
ABSTRACT Dielectric ceramics are popular for energy storage materials because of their rapid charge–discharge characteristics, whereas their low energy density and efficiency hinder their miniaturization and integration. In this work, the energy storage performance is significantly enhanced through introducing Al2O3 and TiO2 into the 0.425(Bi0.5Na0.5 ...
Qiansi Zhang   +9 more
wiley   +1 more source

多重雷击下ZnO避雷器热击穿机理研究 附视频

open access: yesDianci bileiqi, 2022
全国的平均雷击事故率超过50%,在南方地区更是高达70%。造成雷害事故多发的一个重要原因是由ZnO避雷器的热击穿造成的。自然界中75%的雷击过程具有多重性,在多重雷击作用下,ZnO避雷器阀片会持续的流过雷电流和工频短路电流,避雷器阀片柱的温度升高的极快,时间是毫秒级的。本研究将聚焦多重雷击下ZnO避雷器的热击穿问题,通过FLUENT仿真,计算出ZnO避雷器在典型多重雷击作用下发生热击穿时的温度变化过程,并给出解决问题的方向。
doaj  

运行与检修问答

open access: yesGaoya dianqi, 1997
【问】真空断路器切投电容器组时,为什么会发生“延时重击穿”现象? 【答】真空断路器灭弧后的介质恢复速度高达20~25kV/μs,远高于10kV电容器组开断后的电压恢复速度,理应不会发生重燃。而事实并非如此。而且真空断路器的重燃机理又与油断器有着很大的不同。油断器的重燃一般都发生在灭弧后5~10ms间。而真空断路器的重燃大多发生在灭弧后几十~几百ms间,有的甚至长达数s。这种现象称为真空断路器的“延时重击穿”。 真空间隙电击穿的原因,有许多不同的说法。目前一般认为有两种 ...
林立生
doaj  

投切电容器组产生重击穿及NSDD过电压对电容器影响分析

open access: yesGaoya dianqi, 2017
针对真空断路器投切电容器组时发生的重击穿与NSDD所产生的过电压问题,通过对投切电容器组发生重击穿与NSDD典型波形分析,同时5年来真空断路器在投切电容器组的型式试验和老炼试验中发生的重击穿与NSDD次数统计,在中性点不接地系统中,NSDD发生次数远大于重击穿次数,发生重击穿与NSDD在电容器极间与真空断路器断口所产生的过电压基本是没有差异的。因此对NSDD的所产生对电容器的危害是不能忽略的。
李电   +7 more
doaj  

同步开关技术对提高开断电容器组性能的研究

open access: yesGaoya dianqi, 2017
断路器在开断电容器组时引发的重击穿过电压可破坏设备绝缘,对电网的安全运行构成威胁。采用同步开关技术合理延长燃弧时间,可有效降低重击穿概率。文中结合弧隙介质恢复理论与断路器同步关合特性,根据重击穿的判据条件,提出了一种重击穿概率计算新方法,从数理角度分析了触头分离时间、断路器绝缘强度上升率对重击穿概率的影响;再通过35 kV永磁真空断路器动态预击穿试验得到其绝缘介质恢复特性,利用上述计算方法并结合试验数据得出:在分闸动作时间最大允许偏差为±2 ms时,将选相控制器的预设燃弧时间选择在46 ms范围内 ...
方春恩   +4 more
doaj  

Home - About - Disclaimer - Privacy