Results 51 to 60 of about 2,808,871 (212)

Serum Myonectin Levels Are Positively Associated With Physical Function and Lower Frailty‐Related Limitation in Maintenance Hemodialysis Patients: A Cross‐Sectional Study

open access: yesTherapeutic Apheresis and Dialysis, EarlyView.
ABSTRACT Background Maintenance hemodialysis (MHD) patients frequently suffer from frailty, characterized by reduced physical function and poor prognosis. Myokines, such as myonectin, secreted by muscle, are emerging regulators of systemic health. This study investigated the relationship between serum myonectin, adipokines (adiponectin, omentin), and ...
Kenichi Kono   +7 more
wiley   +1 more source

Some Remarks on Rovelli's "Why Gauge?" [PDF]

open access: yes, 2013
Rovelli's "Why Gauge?" offers a parable to show that gauge-dependent quantities have a modal and relational physical significance. We subject the morals of this parable to philosophical scrutiny and argue that, while his overarching point stands, there ...
Teh, Nicholas
core  

Comparison of the operative times and intraocular pressure of sutureless vitrectomy with a 27- versus 25-gauge system in eyes with epiretinal membrane

open access: yesFujita Medical Journal, 2016
Objectives: To compare the time of operation and the postoperative intraocular pressure (IOP) using a 27- versus 25-gauge three-port vitrectomy in eyes with epiretinal membrane (ERM). Methods: The clinical records of eyes with ERM that underwent combined
Mayari Ito   +3 more
doaj   +1 more source

Comparative Evaluation of Hemodiafiltration, Hemoperfusion, and Standard Hemodialysis on Efficacy, Inflammatory Control, Dialysis Adequacy, and Safety in End‐Stage Renal Disease: A Prospective Observational Study

open access: yesTherapeutic Apheresis and Dialysis, EarlyView.
ABSTRACT Background Chronic micro‐inflammation in patients with end‐stage renal disease (ESRD) is a significant driver of cardiovascular complications and diminished quality of life. While standard hemodialysis (SHD) effectively manages small‐molecule clearance, its ability to remove medium‐to‐large uremic toxins—the primary catalysts of systemic ...
Hongwei Zuo   +5 more
wiley   +1 more source

Perioperative changes of the intraocular pressure during the treatment of epiretinal membrane by using 25- or 27-gauge sutureless vitrectomy without gas tamponade

open access: yesClinical Ophthalmology, 2017
Hirotsugu Takashina,1,2 Akira Watanabe,2 Hiroshi Tsuneoka2 1Department of Ophthalmology, National Hospital Organization Sagamihara Hospital, 2Department of Ophthalmology, Jikei University School of Medicine, Tokyo, Japan Purpose: The purpose of this ...
Takashina H, Watanabe A, Tsuneoka H
doaj  

One-year outcomes of 27-gauge versus 25-gauge pars plana vitrectomy for uncomplicated rhegmatogenous retinal detachment repair

open access: yesInternational Journal of Retina and Vitreous, 2019
Background 27-gauge (27G) and 25-gauge (25G) transconjunctival sutureless vitrectomy (TSV) were considered equal about safety, effectiveness and vitrectomy time for the treatment of rhegmatogenous retinal detachment (RRD), although larger and long-term ...
Giancarlo Sborgia   +8 more
doaj   +1 more source

Combined Femtosecond Laser-Assisted Cataract Surgery and 27-Gauge Transconjunctival Sutureless Vitrectomy

open access: yesJournal of Ophthalmology, 2020
Purpose. To report the outcomes of combined surgery using femtosecond laser-assisted cataract surgery (FLACS) and sutureless 27-gauge pars plana vitrectomy with intravitreal tamponade. Methods.
Sami Yılmaz   +2 more
doaj   +1 more source

Safety of Daprodustat for the Treatment of Chronic Kidney Disease Anemia: Final Analysis of a Multicenter Postmarketing Surveillance Study in Japan

open access: yesTherapeutic Apheresis and Dialysis, EarlyView.
ABSTRACT Introduction This final analysis of a multicenter, prospective postmarketing surveillance study evaluated the safety of daprodustat in patients with chronic kidney disease anemia in routine clinical practice in Japan. Methods Patients who initiated daprodustat between September 2020 and July 2022 were registered.
Tadao Akizawa   +7 more
wiley   +1 more source

Are gauge symmetry transformations observable? [PDF]

open access: yes, 2003
In a recent paper in the British Journal for the Philosophy of Science, Kosso discussed the observational status of continuous symmetries of physics. While we are in broad agreement with his approach, we disagree with his analysis.
Brading, Katherine   +3 more
core  

Association Between Individualized Education for Kidney Replacement Therapy Modality Selection and Peritoneal Dialysis Initiation: A Cross‐Sectional Study

open access: yesTherapeutic Apheresis and Dialysis, EarlyView.
ABSTRACT Introduction Peritoneal dialysis (PD) is an established home‐based kidney replacement therapy (KRT), but its uptake remains low in Japan. We evaluated whether individualized education in a dedicated outpatient clinic was associated with the initiation of PD.
Yasuko Ito   +7 more
wiley   +1 more source

Home - About - Disclaimer - Privacy