Results 101 to 110 of about 11,242 (161)
Abstract The ChE- and AE- activities and the 32 P-concentration of the plasma from rats 1 and 24 hr after s.c. injection of 32 P-sarin (200 μg kg ) were measured. One hr after the injection the ChE was inhibited to approx. 10 per cent and the AE to 40–50 per cent; 23 hr later 50 per cent of the ChE activity was found to be restored and the AE
Polak, R.L., Cohen, E.M.
openaire +4 more sources
The time course of the changes of the counting rate caused by 32P is determined in six commercially available scintillation mixtures applicable to aqueous solutions of the samples. The measurements were performed separately in the 3H- and 32P-measuring channels.
Radimír Rexa, Richard Tykva
openaire +2 more sources
32P-Postlabeling Analysis of DNA Adducts
32P-Postlabeling analysis is an ultra-sensitive method for the detection of DNA adducts, such as those formed directly by the covalent binding of carcinogens and mutagens to bases in DNA, and other DNA lesions resulting from modification of bases by endogenous or exogenous agents (e.g., oxidative damage).
Phillips, David H, Arlt, Volker M
openaire +5 more sources
Some of the next articles are maybe not open access.
Related searches:
Related searches:
32P-labeling of bovine tryptophanyl-tRNA synthetase with [32P]pyrophosphate
Molecular Biology Reports, 1981The covalent derivative of the tryptophanyl-tRNA synthetase obtained under the action of32PPi contains one mole of the covalently bound pyrophosphate (or 2 moles of orthophosphate) per mole of dimeric enzyme. Dephosphorylation with alkaline phosphatase causes practically no changes of enzymatic activity although the enzyme looses its ability to bind ...
G K, Kovaleva +2 more
openaire +2 more sources
Nuclear Physics A, 1973
Abstract Particle-gamma angular correlations have been measured with the 29 Si(α,pγ) 32 P reaction at bombarding energies E α = 10.65, 10.69 and 11.00 MeV. Together with DSA lifetime measurements these experiments lead to seven unambiguous spin assignments to levels below 3.5 MeV excitation energy in 32 P.
F.E.H. Van Eijkern +3 more
openaire +1 more source
Abstract Particle-gamma angular correlations have been measured with the 29 Si(α,pγ) 32 P reaction at bombarding energies E α = 10.65, 10.69 and 11.00 MeV. Together with DSA lifetime measurements these experiments lead to seven unambiguous spin assignments to levels below 3.5 MeV excitation energy in 32 P.
F.E.H. Van Eijkern +3 more
openaire +1 more source
In vitro transfer of [32P]-label from α-[32P]-dATP into ribonucleotides
Biochemical and Biophysical Research Communications, 1977Abstract During the incorporation of α-[ 32 P]-dATP into HeLa cell nuclei some of the [ 32 P]-label enters ribonucleic acid presumably because of intracellular nucleotide turnover. This result makes the conclusion about the existence of an RNA-DNA covalent linkage, based on the transfer of [ 32 P]-label from deoxyribonucleotides to ribonucleotides ...
D, Hartman, R, Werner
openaire +2 more sources
The labelling of human serum by 32P-DiIsopropylphosphorofluoridate (DF32P)
Biochimica et Biophysica Acta, 19571. 1. On paper electrophoresis the pseudo-cholinesterase activity of human serum is localised between the α-2 and the β-peak. 2. 2. The same localisation is found after electrophoresis on starch columns. 3. 3. Thoroughly dialysed DF32P treated human sera as well as sera obtained from humans a few days after the injection of DF32P were submitted to zone
Cohen, J.A., Warringa, M.G.P.J.
openaire +3 more sources
32P-therapy in polycythemia vera
Klinische Wochenschrift, 1975A group of 52 consecutive patients with polycythemia vera was submitted to long-term therapy with radioactive phosphorus (32P). Initial phase of therapy induced complete remissions (normalization of hematogram; spleen not palpable) in 45% of the patients, and partial remissions in the remaining 55%.
G, Meuret, G, Hoffmann, R, Gmelin
openaire +2 more sources
Development of Microplate-radioluminography for 32P
Applied Radiation and Isotopes, 1998Basic research for designing a microplate which can be applied to determination of 32P by radioluminography was carried out. It was proven that 32P can be determined by using the microplate which has plural planchets placed at intervals on a thin plate and a brass collimator that fills the gaps between the planchets.
S, Baba +5 more
openaire +2 more sources
Complications Associated with Intraperitoneal 32P
Gynecologic Oncology, 1994The charts of all patients having received intraperitoneal 32P in the Indiana University Department of Radiation Oncology were retrospectively reviewed for complications and potentially related factors. Ninety-five patients had received this therapy, with a mean follow-up of 43.6 months. The majority of patients (81) had ovarian cancer.
M, Tharp, N B, Hornback
openaire +2 more sources

