Results 41 to 50 of about 195 (114)
Young's modulus of polyelectrolyte multilayers from microcapsule swelling
We measure Young's modulus of a free polyelectrolyte multilayer film by studying osmotically induced swelling of polyelectrolyte multilayer microcapsules filled with the polyelectrolyte solution.
Andrienko, D. +4 more
core +1 more source
Assessing donor/recipient HLA compatibility at the eplet level requires second field DNA typings but these are not always available. These can be estimated from lower‐resolution data either manually or with computational tools currently relying, at best, on data containing typing ambiguities.
Romain Lhotte +22 more
wiley +1 more source
Modelado de Materiales Compuestos por Elementos Finitos usando Restricciones Cinemáticas
El propósito de este artículo es presentar simulaciones del comportamiento de materiales compuestos basado en restricciones cinemáticas entre las mismas fibras y entre las fibras y la resina circundante.
Oscar E. Ruiz +4 more
doaj
Elasticity of polyelectrolyte multilayer microcapsules
We present a novel approach to probe elastic properties of polyelectrolyte multilayer microcapsules. The method is based on measurements of the capsule load-deformation curves with the atomic force microscope.
Andrienko, D. +2 more
core +1 more source
Doping-Dedoping-Driven Optic Effect of pi-Conjugated Polymers Prepared in Cholesteric-Liquid-Crystal Electrolytes [PDF]
journal ...
GOTO Hiromasa
core +1 more source
A Computational Model for Continuous Cooling of Injection Moulding Processes [PDF]
This paper discusses the approaches and techniques used to build a realistic numerical model to analyse the cooling phase of the injection moulding process.
Allan, PS +4 more
core
Waveplate retarders based on overhead transparencies
We describe procedures for constructing inexpensive waveplates of desired retardation out of ordinary commercially available transparencies. Various relevant properties of the transparencies are investigated: the dependence of retardation on rotation of ...
Elman +6 more
core +1 more source
START as the detector of choice for large-scale muon triggering systems [PDF]
Further progress in building high-granular large-scale systems based on Scintillation Tiles with MRS APD light readout (START) became possible thanks to the creation of an improved version of MRS APD.
Akindinov, A. +11 more
core +2 more sources
Glass transition and alpha-relaxation dynamics of thin films of labeled polystyrene
The glass transition temperature and relaxation dynamics of the segmental motions of thin films of polystyrene labeled with a dye, 4-[N-ethyl-N-(hydroxyethyl)]amino-4-nitraozobenzene (Disperse Red 1, DR1) are investigated using dielectric measurements ...
A. Dhinojwala +6 more
core +1 more source
Designing polymers for nuclear track detection [PDF]
This article describes our attempts since 1996 to systematically design andsynthesize monomers and corresponding polymers for nuclear track detection. So far more than 15 homopolymers.copolymers have been prepared and tested by us for this purpose.
Nadkarni, V S
core +1 more source

