Results 231 to 240 of about 1,269,928 (298)

Reducing Pipeline AC Interference by Phase Permutation

open access: yesMaterials Performance
High-voltage power lines can induce alternating current (AC) voltages on nearby gas pipelines, creating safety and corrosion risks. This article presents a French case study involving three gas pipelines exposed to severe interference from a 225 kV dual-circuit line over 17 km (10.6 mi).A Initial simulations predicted voltages approaching 200 V in the ...
Paola Daza Acevedo   +3 more
openaire   +2 more sources
Some of the next articles are maybe not open access.

Related searches:

Obtaining the Polarized Potential under AC Interference

CONFERENCE 2022, 2022
Abstract Obtaining the polarized potential (off potential / instant-off potential / IR compensated potential) of a pipeline is considered extremely difficult, if not impossible, when the pipeline is interfered by an alternating voltage, and particularly if the pipeline is fitted with capacitive AC mitigation devices.
Andreas Junker Olesen   +1 more
openaire   +1 more source

Prediction and mitigation of AC interference on the pipeline system

Corrosion Reviews, 2022
Abstract The purpose of this paper is to predict and mitigate AC interference on buried pipeline systems due to transmission lines. Modeling and field verification of AC interference is done. The article also presents the issue of optimizing the mitigation measures. The paper uses the field data on soil resistivity, transmission line,
Ajit Kumar Thakur   +2 more
openaire   +1 more source

Effects of AC-Interference on Passive Metals Corrosion

CORROSION 2011, 2011
Abstract AC-induced corrosion continues to be a controversial subject and a full agreement on influencing parameters and mechanism has not yet been achieved. The influence of AC-induced interference on the localized corrosion resistance of passive metals is discussed on the basis of laboratory test results.
ORMELLESE, MARCO   +2 more
openaire   +2 more sources

CP Criteria Assessment in the Presence of AC Interference

CORROSION 2008, 2008
Abstract The presence of AC may cause serious damage on metallic structures even when cathodic protection is applied and off-potential matches −0.85 V CSE criterion. Uncertainties still exist on protection potential interval and on protection current density to reach an acceptable protection when AC interference is present.
ORMELLESE, MARCO   +3 more
openaire   +2 more sources

Guidelines for AC Interference Prediction and Control

CORROSION 1983, 1983
Abstract This paper is intended as an overview of the AC induction problems that can be experienced by the pipeline industry jointly sharing rights of way with overhead powerlines. Concerns to be addressed during the planning of a joint corridor concept are listed and discussed.
John Dabkowski, Marvin Frazier
openaire   +1 more source

Home - About - Disclaimer - Privacy