Results 251 to 260 of about 1,269,928 (298)
Some of the next articles are maybe not open access.
Effects of AC interference on photovoltages of junction diodes
IEEE Transactions on Electromagnetic Compatibility, 1995The effects of ac interference on the photovoltage of diodes are analyzed experimentally and theoretically. The dependence of the interference susceptibility on the power and wavelength of incident light is shown. The frequency dependence of the interference effect is also illustrated. A model of the interference path is proposed and verified.
null Cheng-Kuang Liu +2 more
openaire +1 more source
Influence of Pipeline Electric Parameters on AC Interference
CORROSION 2010, 2010Abstract Induction in the pipeline due to AC interference is a phenomenon that should be taken into account for planning and mitigating purposes. To evaluate the electric currents and voltages produced in the pipeline due to proximity of high voltage power lines, Transmission Line Theory (TLT) is often applied and a number of software ...
openaire +1 more source
AC corrosion interference of buried long distance pipeline
2021 3rd International Conference on Intelligent Control, Measurement and Signal Processing and Intelligent Oil Field (ICMSP), 2021The interference law and calculation model of AC transmission lines and other AC facilities on buried long distance pipeline are briefly described. The main influence law of AC current on the passivation behavior of pipeline steel materials is summarized.
Lin Li, Xinyao Gao
openaire +1 more source
Variances in Pipeline Ac Interference Computational Modeling
CORROSION 2019, 2019Abstract The AC interference between High Voltage AC (HVAC) power lines and pipelines has been modeled with various software programs, all of which have a variety of input data which creates various results and outputs. Important aspects such as the soil resistivity along the pipeline route can have a significant impact on the pipelines ...
Gerald J Haynes +3 more
openaire +1 more source
Frequency Dependence in AC Harmonic Interference to Pipelines
CORROSION 2018, 2018Abstract Studies of Alternating Current (AC) interference on pipelines from nearby power lines usually consider the fundamental (50Hz or 60Hz) frequency of the power line currents. However, these currents can also contain considerable harmonics of the fundamental AC frequency.
L. Trichtchenko, D.H. Boteler
openaire +1 more source
Klinische Wochenschrift, 1989
In healthy volunteers the acute effect of furosemide (40 mg i.v.) and hydrochlorothiazide (100 mg p.o.) on diuresis, natriuresis and renal kallikrein and kinin excretion was investigated. Furosemide stimulated markedly diuresis and natriuresis as well as urinary kallikrein and kinin excretion.
C, Toussaint +4 more
openaire +2 more sources
In healthy volunteers the acute effect of furosemide (40 mg i.v.) and hydrochlorothiazide (100 mg p.o.) on diuresis, natriuresis and renal kallikrein and kinin excretion was investigated. Furosemide stimulated markedly diuresis and natriuresis as well as urinary kallikrein and kinin excretion.
C, Toussaint +4 more
openaire +2 more sources
Study on Factors Influencing the Mitigation of AC Interference
CORROSION 2012, 2012Abstract Recently, pipelines are being constructed in parallel with high voltage power lines due to industrial development. This results in AC interference which gets more and more attentions for leading to electric shocks and accelerating corrosion of pipelines. A mitigation system can decrease AC potential and AC corrosion. Design of a
Zitao Jiang +3 more
openaire +1 more source
Optimal Phasing for Parallel Transmission Lines to Minimize AC Interference
2018 IEEE Canadian Conference on Electrical & Computer Engineering (CCECE), 2018AC interference is a growing concern within the power industry due to the proximity of other utilities (pipelines, railways, etc.) sharing the same right-of-way (ROW) and corresponding safety issues. This paper presents a methodology for determining the optimal phasing of power transmission lines to reduce the interference and improve on safe operation
Arash Tavighi +3 more
openaire +2 more sources
Detection and Mitigation of AC Interference on 200km Pipeline
Volume 2: Pipeline Integrity Management, 2012The AC interference on pipelines caused by nearby HVAC power lines and electrified railways can lead to electric shock hazard and AC corrosion, which threatens the safety of pipeline and has attracted more and more attention. A 300km-long pipeline in the north of China is close to many HVAC power lines and electrified railways and there exists a high ...
Yanxia Du, Zitao Jiang, Minxu Lu
openaire +1 more source
Accurate Modeling and Troubleshooting of AC Interference Problems on Pipelines
CORROSION 2012, 2012Abstract Cases of close proximity of high voltage transmission lines and metallic pipelines become more and more frequent in high population density regions. Therefore, there is a growing concern about possible hazards resulting from the influence of electrical systems: safety of people making contact with the pipeline, damage to the ...
L. Bortels +2 more
openaire +1 more source