Results 261 to 270 of about 1,269,928 (298)
Some of the next articles are maybe not open access.

Conducted interference voltage of AC-DC converters

1986 17th Annual IEEE Power Electronics Specialists Conference, 1986
In this article an analytical method for calculating the conducted interference voltages of the three basic ac-dc converters buck, boost and buck-boost with sinusoidal input current and unity power factor is presented. The analysis includes a simulation of the quasi-peak measurement according to CISPR (Comite International Special des Perturbations ...
openaire   +1 more source

Frequency dependence of AC-interference susceptibility in digital ICs

IEE Proceedings - Science, Measurement and Technology, 1995
A study is made of the frequency dependence of AC-interference susceptibility in ICs. The effects of AC energy, picked up from the environment by a TTL IC, on the response of the victim are analysed experimentally and numerically. The experimental results of NAND gates interfered by AC signals with frequencies below 450 MHz are shown.
C.-K. Liu, C.-J. Ho
openaire   +1 more source

Mitigating Pipeline AC Interference Using Numerical Modeling and Continuous AC Voltage Monitoring

CORROSION 2018, 2018
Abstract With the rapid construction of high voltage alternating current (AC) transmission lines, AC interference problem is becoming a new threat to the pipeline safety, especially for pipelines coated with high quality coating, such as 3PE+.
Jiang Youwen   +4 more
openaire   +1 more source

Assessment of Inductive AC Interference Mitigation Strategies

Materials Performance
Inductive alternating current (AC) interference on new and existing pipeline systems that cross, or are parallel with, overhead power lines is a serious concern. Two main issues are associated with this phenomenon: The electrical safety risk to pipeline personnel, sub-contractors working on a pipeline system, and the general public arises if any ...
openaire   +1 more source

The adoption of new concepts in AC traction interference control

International Conference on Developments in Mass Transit Systems, 1998
Brush Traction has a long history in the development of AC drives including the World's first locomotive using inverter fed induction motors. With the introduction of 3-phase drives into the UK came a new interest in signalling compatibility. This led to major development programmes in which the system design for signalling compatibility became a ...
openaire   +1 more source

A Survey on Coping With Intentional Interference in Satellite Navigation for Manned and Unmanned Aircraft

IEEE Communications Surveys and Tutorials, 2020
Emanuela Falletti   +2 more
exaly  