Results 241 to 250 of about 1,269,928 (298)
Some of the next articles are maybe not open access.

Proposal of CP Criterion in the Presence of AC-Interference

CORROSION 2010, 2010
Abstract In order to assess cathodic protection (CP) criteria in the presence of alternate current (AC) interference, weight loss tests on cathodically protected carbon steel specimens (CP current density in the range of 0.2 to 10 A/m2) were performed in soil-simulated conditions in the presence of AC densities ranging from 10 to about ...
ORMELLESE, MARCO   +3 more
openaire   +2 more sources

An ac-dc converter with reduced electromagnetic interference

Canadian Journal of Electrical and Computer Engineering, 1994
The circuit proposed in this paper causes considerably reduced electromagnetic interference (EMI) and harmonic current distortion on the utility supply network in comparison to existing power supplies that are used in electronic equipment (computers, television sets, etc.).
Rémy Simard, Venkatachari Rajagopalan
openaire   +1 more source

Mitigating AC and DC Interference in Multi-ToF-Camera Environments

IEEE Transactions on Pattern Analysis and Machine Intelligence, 2023
Multi-camera interference (MCI) is an important challenge faced by continuous-wave time-of-flight (C-ToF) cameras. In the presence of other cameras, a C-ToF camera may receive light from other cameras' sources, resulting in potentially large depth errors. We propose stochastic exposure coding (SEC), a novel approach to mitigate MCI.
Jongho Lee 0004, Mohit Gupta 0001
openaire   +2 more sources

Laboratory Test Results of AC Interference on Polarized Steel

CORROSION 2003, 2003
Abstract This paper illustrates the results of laboratory tests on the influence of AC interference on carbon steel corrosion under different conditions, i.e. free corrosion, anodic or cathodic polarization. Anodic polarization simulates corrosion conditions of buried structures in the presence of galvanic coupling, typically with bare ...
BOLZONI, FABIO MARIA   +3 more
openaire   +2 more sources

Study on AC interference law of high voltage AC cable to submarine pipeline and safe distance

Materials and Corrosion, 2022
AbstractIn recent years, due to the large‐scale construction of wind power and shore power projects, the amount of submarine high‐voltage AC cables has been increasing year by year, and they often form a “common corridor” in parallel with adjacent submarine pipelines, resulting in AC interference on pipelines.
Zhenhong Zhu   +4 more
openaire   +1 more source

AC Interference and Mitigation: Heartland Case Study

CORROSION 2017, 2017
Abstract Alternating Current (AC) Interference and Mitigation (ACIM) is becoming an increasingly common occurrence in the pipeline industry. This paper describes the challenges associated with coordinating the modelling, design, and installation of ACIM systems for a complex ACIM project located in Edmonton, Alberta, Canada, with a final
Matthew Lechelt, Kelly Fletcher
openaire   +1 more source

AC Interference Risk Ranking: Case Study

CORROSION 2016, 2016
Abstract As utility corridors become increasingly congested, AC interference on pipelines due to collocation with high voltage AC (HVAC) transmission powerlines continues to be a growing concern. Many pipeline operators have large quantities of existing pipeline infrastructure that has not been fully assessed to determine whether it is ...
Wolfgang Fieltsch, Daniel Silva
openaire   +1 more source

Challenges in Mitigating Ac Interference in Remote Areas

CORROSION 2017, 2017
Abstract An AC interference study was conducted in 2015 following the installation of a new 240 kV powerline in a remote area of Alberta, Canada. The calculations indicated severe risk of AC corrosion for the paralleling pipelines and safety hazards for pipeline personnel, especially under fault conditions ...
M. Luk, D. Hebb, E. Gudino, C. Khattar
openaire   +1 more source

Effect of AC interference on cathodic protection monitoring

Corrosion Engineering, Science and Technology, 2011
Cathodic protection (CP) monitoring in the presence of simultaneous AC and DC interference could lead to erroneous measurements, since IR drop contribution due to both DC and AC could heavily affect potential readings. Therefore, to know the true potential (or true polarisation level), the ohmic drop contribution has to be eliminated.
ORMELLESE, MARCO   +2 more
openaire   +1 more source

Measurements of Higher Harmonics in AC Interference on Pipelines

CORROSION 2010, 2010
Abstract Recordings of alternating current (AC) pipe to soil potential (PSP) variations have been made using fast-sample (2000 samples/sec) dataloggers. This sampling rate is fast enough to show the waveform of the AC potential variations.
D. H Boteler, S. Croall, P. Nicholson
openaire   +1 more source

Home - About - Disclaimer - Privacy