Results 161 to 170 of about 1,146,309 (300)
A spiral microfluidic chip is compared with ultrafiltration for the separation of extracellular vesicles (EVs). The method preserves miRNA cargo and membrane integrity more effectively, resulting in intact vesicle morphology and consistent surface biomarker expression.
Huiseop Lee +5 more
wiley +1 more source
Non‐Invasive Multidimensional Capacitive Sensing for In Vivo Traumatic Brain Injury Monitoring
Single‐electrode, multidimensional capacitive sensors noninvasively assess cerebral autoregulation and compliance for traumatic brain injury monitoring. ABSTRACT Traumatic brain injury (TBI) is a major cause of death and disability, but invasive intracranial pressure (ICP) monitoring is risky, and current non‐invasive methods lack the resolution and ...
Shawn Kim +8 more
wiley +1 more source
Role of gas nuclei in ultrasonic atomization in acoustic fountains: mechanisms and experimental evidence. [PDF]
Gao Y, Bai L, Deng J, Sun J, Bai L.
europepmc +1 more source
ABSTRACT Quantifying oral polymorphonuclear neutrophils (oPMNs) is a clinically validated approach for assessing periodontal inflammation. However, current methods, such as manual hemocytometry and flow cytometry, are time‐consuming (>3 h), require invasive sampling, and depend on staining and complex instrumentation, making them unsuitable for point ...
Mohsen Hassani +9 more
wiley +1 more source
Contrastive learning for passive acoustic monitoring: A framework for sound source discovery and cross-site comparison in marine soundscapes. [PDF]
Acs R +3 more
europepmc +1 more source
Combined approach of electromagnetic (Power) and ultrasound (data harvesting) waves is proposed to address the miniaturized ultrasonic implants. Electromagnetic waves trigger the piezoelectric element to generate the acoustic pulse which is modulated by the variations in the sensor's impedance.
Anam Bhatti +6 more
wiley +1 more source
Subwavelength imaging with a zero-mass sonic meta-atom. [PDF]
Devaux T +6 more
europepmc +1 more source
Hierarchical multi‐material TPMS lattices are engineered as flexible tactile sensors by combining soft and stiff elastomeric layers with a conformal conductive coating. The bilayer architecture delivers sensitivity at low pressures while maintaining a broad detectable range under large loads, enabling reliable pressure and vibration monitoring for ...
Reza Noroozi +3 more
wiley +1 more source
A cochlea bio-inspired tunable piezoelectric cantilever array MEMS microphone: comprehensive study. [PDF]
Zheng Z +9 more
europepmc +1 more source
Flexible piezopolymer ultrasound transducers are engineered by tailoring the electrode–piezopolymer interface using metallic, flake‐based, and porous graphene electrodes. Laser‐induced graphene's porous structure enables polymer infiltration, strengthening interfacial coupling and enhancing piezoelectric response and acoustic output.
Spencer Hagen +3 more
wiley +1 more source