Results 71 to 80 of about 1,134,965 (196)
A feasibility study of an adaptive reclosing relay
Logic for an adaptive reclosing relay has been developed. The relay works correctly in a wide number of fault cases. The relay has the following distinguishing characteristics : (a) Reclosing into a three phase fault is avoided under all circumstances.
Vaidyanathan, Sundararaman
core
A Study of a Optimal reclosing in power system [PDF]
This paper proposes the optimum reclosing operating method. The proposed method calculates the optimum time, taking the case as a standard in which the reclosing is not done.
藤田, 淳也 +8 more
core +1 more source
python-adaptive/adaptive: version 0.15.0
What's Changed Rename master -> main by @basnijholt in https://github.com/python-adaptive/adaptive/pull/384 Add docs section about executing coroutines by @juandaanieel in https://github.com/python-adaptive/adaptive/pull/364 Add loss_goal, npoints_goal,
Weston, Joseph +3 more
core +1 more source
Two‐Stage Dual Signal Processing Algorithms‐Based Protection Strategy for AC Microgrids
This paper proposes a novel dual‐algorithm protection strategy for AC microgrids, integrating a Discrete Unscented Kalman Filter (DUKF) with a One‐Dimensional Sliding Window Median Filter (ODSWMF). ABSTRACT Smart protection methods are essential for modern AC microgrids, as they must be capable of detecting faults quickly, accurately, and reliably ...
Muneer Ahmed +4 more
wiley +1 more source
This paper presents an LQR‐based strategy for seamless transition between grid‐forming and grid‐following inverters in microgrids. The proposed design integrates the comprehensive control loops of the grid‐forming and grid‐following inverters. A systematic, gradient‐based optimization framework is used for selecting the weighting matrices.
Adel Tatish, Kanchapogu Vaisakh
wiley +1 more source
Performance Analysis of Distance Relay in the Presence of Grid‐Forming Inverter
The primary objective of this paper is to investigate the impact of IBRs on transmission line protection in detail. Given that distance protection is extensively used for safeguarding transmission lines and that maloperation of distance relays can have a significant impact on overall system stability, the focus of this work is on distance protection ...
Mehdi Mohammadi +2 more
wiley +1 more source
An Analysis of Optimal Reclosing for Enhancement of Transient Stability [PDF]
In a power system, the auto-reclosing schemes are applied in order to enhance the transient stability. However, conventional auto-reclosing techniques adopt fixed time interval reclosing, that is, the circuit breakers reclose after a prescribed dead time.
矢神, 雅規 +2 more
core +1 more source
Applying series braking resistors to improve the stability of low inertia synchronous generators [PDF]
Widely held concerns over the environmental impact of emissions from large fossil fuelled generating plants are serving to promote the connection of renewable or sustainable generation onto distribution networks.
Bright, C.G. +4 more
core +4 more sources
A Methodology to Prevent Failure in Single Pole Reclosing Operations
After a phase to earth fault in a transmission line, opening of the circuit breaker poles at line extremities interrupts the fault current in the faulted phase.
Pablo Mourente Miguel
core +1 more source
The distribution network line has the risk of an unsuccessful three-phase blind reclosing in permanent fault. Based on the response of the inverter of the distributed generation (DG) to the short-term low-frequency voltage disturbance to the line to be ...
Zhebin Sun +5 more
doaj +1 more source

