Improved digital algorithm for adaptive reclosing for transmission lines with shunt reactors

open access: yesIET Generation, Transmission & Distribution, 2016
This study presents an improved algorithm of adaptive single‐phase auto‐reclosing (ASPAR) for extra high voltage transmission lines with shunt reactors. It shows that the odd and even harmonic factors of the faulted phase voltage have different characteristic in different stages after breaker open.
Xunhua Luo, Chun Huang, Yaqun Jiang
openaire   +1 more source

Online Calculation for the Optimal Reclosing Time of Transmission Lines

open access: yes, 2016
Circuit breakers should be reclosed at the optimal reclosing time in order to enhance the transient stability of a power system after disturbances.
Liu, Pei   +6 more
core   +1 more source

Intelligent-single-phase auto-reclosing scheme using line-voltage-phasor-side analysis

open access: yesResults in Engineering
Due to the extended length of transmission lines, electrical equipment is frequently exposed to various faults. To ensure a continuous supply of electricity to consumers and maintain the stability of the power grid, the implementation of reconnection ...
Mohammad Hassan Tanha   +3 more
doaj   +1 more source

Distibuted generation and reclosing coordination

open access: yes, 2004
Distributed generation has many detrimental impacts on reclosing. DG may continue operation during the dead time feeding fault current and thus prevent arc extinction.
Kauhaniemi, Kimmo, Kumpulainen, Lauri
core   +3 more sources

Quasi-single phase permanent fault identification method and reclosing strategy based on multi-level confidence rules

open access: yesInternational Journal of Electrical Power & Energy Systems
As global temperatures rise, the frequency of lightning increases, making lightning one of the principal threats to power-system security. Field incidents indicate that, within the automatic reclosing time window, multiple-stroke lightning can exhibit ...
Hongchun Shu   +7 more
doaj   +1 more source

A novel thyristor-based hybrid DC circuit breaker with the ability to identify the type and location of the fault before reclosing the MMC-HVDC grid

open access: yesInternational Journal of Electrical Power & Energy Systems
Although HVDC grids offer significant advantages in the widespread integration of renewable sources and the transmission of their generated power to distant areas, distrust remains regarding their performance under fault conditions.
Mojtaba Roshani Diz   +2 more
doaj   +1 more source

A Communication-Free Cooperative Fault Recovery Control Method for DNs Based on Staged Active Power Injection of ES

open access: yesEnergies
To address the reclosing failures in the distribution networks (DNs) with high penetration of distributed energy resources (DERs), this paper proposes a communication-free cooperative fault recovery control method based on staged active power injection ...
Bin Yang   +4 more
doaj   +1 more source

A novel thyristor‐based hybrid DC circuit breaker with short arcing capability

open access: yesHigh Voltage
Multi‐terminal flexible high‐voltage direct current (HVDC) transmission and DC grid technology are developing rapidly. The hybrid DC circuit breaker (HCB) has broad application prospects in the field of HVDC transmission and DC power grid.
Guanlong Jia   +4 more
doaj   +1 more source

Active arc suppression based MMC-HVDC DC fault adaptive reclosing

open access: hybrid, 2023
Zainan Li   +5 more
openalex   +1 more source