Results 61 to 70 of about 169 (151)

Molecular Basis for Vacuolar Iron Transport by OsVIT2, a Target for Iron Biofortification in Rice

open access: yesProteins: Structure, Function, and Bioinformatics, Volume 93, Issue 10, Page 1717-1731, October 2025.
ABSTRACT Iron deficiency is the prevalent and most widespread nutritional shortfall for humans, affecting over 30% of the global population and leading to anemia, particularly among preschool‐aged children and pregnant women in developing countries. Simultaneously, while half of the world's population depends on rice (Oryza sativa L.) as a staple food,
L. B. Arend   +4 more
wiley   +1 more source

An efficient deep learning based scheme for adaptive auto-reclosing in power transmission lines

open access: yesAlexandria Engineering Journal
As a large percentage of faults in transmission lines are single-line-to-ground (SLG) and transient in nature, the use of adaptive single-phase auto-reclosing (ASPAR) schemes is essential.
Farhad Hatami Aloghareh   +2 more
doaj   +1 more source

Improved digital algorithm for adaptive reclosing for transmission lines with shunt reactors

open access: yesIET Generation, Transmission & Distribution, 2016
This study presents an improved algorithm of adaptive single‐phase auto‐reclosing (ASPAR) for extra high voltage transmission lines with shunt reactors. It shows that the odd and even harmonic factors of the faulted phase voltage have different characteristic in different stages after breaker open.
Xunhua Luo, Chun Huang, Yaqun Jiang
openaire   +1 more source

Intelligent-single-phase auto-reclosing scheme using line-voltage-phasor-side analysis

open access: yesResults in Engineering
Due to the extended length of transmission lines, electrical equipment is frequently exposed to various faults. To ensure a continuous supply of electricity to consumers and maintain the stability of the power grid, the implementation of reconnection ...
Mohammad Hassan Tanha   +3 more
doaj   +1 more source

Adaptive Single Phase Auto-Reclosing Using Voltage Magnitude Pattern

open access: yes, 2020
This paper presents a novel adaptive single phase auto-reclosing (ASPAR) scheme based on the first derivation of local voltage magnitude (VM) of the faulted phase for determination of dead time of transient faults. The algorithm is fast and uses low-frequency sampling and adaptive threshold value (ATV).
Baayeh, Arman Ghaderi, Jamali, Sadegh
openaire   +1 more source

Quasi-single phase permanent fault identification method and reclosing strategy based on multi-level confidence rules

open access: yesInternational Journal of Electrical Power & Energy Systems
As global temperatures rise, the frequency of lightning increases, making lightning one of the principal threats to power-system security. Field incidents indicate that, within the automatic reclosing time window, multiple-stroke lightning can exhibit ...
Hongchun Shu   +7 more
doaj   +1 more source

A novel thyristor-based hybrid DC circuit breaker with the ability to identify the type and location of the fault before reclosing the MMC-HVDC grid

open access: yesInternational Journal of Electrical Power & Energy Systems
Although HVDC grids offer significant advantages in the widespread integration of renewable sources and the transmission of their generated power to distant areas, distrust remains regarding their performance under fault conditions.
Mojtaba Roshani Diz   +2 more
doaj   +1 more source

A Communication-Free Cooperative Fault Recovery Control Method for DNs Based on Staged Active Power Injection of ES

open access: yesEnergies
To address the reclosing failures in the distribution networks (DNs) with high penetration of distributed energy resources (DERs), this paper proposes a communication-free cooperative fault recovery control method based on staged active power injection ...
Bin Yang   +4 more
doaj   +1 more source

A novel thyristor‐based hybrid DC circuit breaker with short arcing capability

open access: yesHigh Voltage
Multi‐terminal flexible high‐voltage direct current (HVDC) transmission and DC grid technology are developing rapidly. The hybrid DC circuit breaker (HCB) has broad application prospects in the field of HVDC transmission and DC power grid.
Guanlong Jia   +4 more
doaj   +1 more source

A review of arc in open air modeling: Fundamental concepts, influential parameters, modeling, and software implementation

open access: yesResults in Engineering
An electrical arc in open air (EAOA) represents one of the most complex and critical phenomena in power systems, whose occurrence on transmission lines directly affects network reliability and stability while playing a decisive role in insulation design,
Mahyar Abasi   +2 more
doaj   +1 more source

Home - About - Disclaimer - Privacy