An Enhanced Electrochemiluminescence Immunoassay Platform via Optimized Magnetic Bead Uniformity for Reliable Thyroid-Stimulating Hormone Monitoring. [PDF]
Lei H, Huang X, Cao X, Tang Y, Ge Y.
europepmc +1 more source
This study investigates H4TBAPy‐based metal–organic frameworks (MOFs) ‐ NU‐1000, NU‐901, SrTBAPy, and BaTBAPy ‐ for multiphoton absorption (MPA) performance. It observes topology‐dependent variations in the 2PA cross‐section, with BaTBAPy exhibiting the highest activity.
Simon N. Deger +10 more
wiley +1 more source
From Invisibility to Inclusion: Evidence, Lived Experience, and Policy Directions for Multiple Chemical Sensitivity Report from the Resilience 2025 International Conference. [PDF]
Vangala K +3 more
europepmc +1 more source
Selective Benzene Capture by Metal‐Organic Frameworks
Metal‐organic frameworks (MOFs) hold significant potential for capturing benzene from air emissions and hydrocarbon mixtures in liquid phases. This capability stems from their precisely engineered structures, versatile chemistries, and diverse binding interactions.
Zongsu Han +4 more
wiley +1 more source
First principles study of flat silicon rich 2D alloys Si<sub>x</sub>Be<sub>y</sub>. [PDF]
Takahashi M.
europepmc +1 more source
Laser‐Induced Graphene from Waste Almond Shells
Almond shells, an abundant agricultural by‐product, are repurposed to create a fully bioderived almond shell/chitosan composite (ASC) degradable in soil. ASC is converted into laser‐induced graphene (LIG) by laser scribing and proposed as a substrate for transient electronics.
Yulia Steksova +9 more
wiley +1 more source
Air, Noise, and Light Pollution and Thromboembolic Cardiovascular Complications: A TH Scientific Statement. [PDF]
Kurasz A +17 more
europepmc +1 more source
Controlled syntheses of lanthanide coordination polymers based on the dihydroxybenzoquinone (DHBQ) organic linker afforded large single crystals of Ln‐DHBQ CPs (Ln = Yb, Nd). A novel structural variant of Yb‐DHBQ is identified by means of single crystal diffraction analysis.
Marina I. Schönherr +7 more
wiley +1 more source
Lithography-free, Pd-based bimorph cantilever switches for zero-standby-power chemo-mechanical H<sub>2</sub> detection. [PDF]
Koh D, Jo E, Kim J.
europepmc +1 more source
For the first time, a highly sensitive electrochemical biosensor based on SiO2‐based hairy particles with a grafted PDMAEMA polymer brush containing a quantifiable and large amount of immobilized Laccase is reported. The fabricated biosensor exhibits a sensitivity of 0.14 A·m⁻¹, a limit of detection (LOD) of 0.1 µm, and a detection range of 0.3–750 µm,
Pavel Milkin +7 more
wiley +1 more source

