Results 61 to 70 of about 8,576 (208)
Effect of thyroid shielding during mammography : measurements on phantom and patient as well as estimation with Monte Carlo simulation [PDF]
Background: During mammography, the thyroid is exposed to scattered radiation from breast tissue and device. This may increase the risk of radiation induced thyroid cancer. Methods: We investigated the scatter radiation exposition of the thyroid and the
Eschle, Patrik +5 more
core +1 more source
Abstract Background The IEC exposure index (EI), deviation index (DI), and target exposure index (EIT), represent critical standardized metrics for the evaluation of exposure and quality in radiographic imaging. Purpose This work develops and validates a systematic procedure to estimate the EIT for eight of the most common radiography imaging protocols
Matthew Hoerner +9 more
wiley +1 more source
EPR dosimetry in a mixed neutron and gamma radiation field [PDF]
Suitability of Electron Paramagnetic Resonance (EPR) spectroscopy for criticality dosimetry was evaluated for tooth enamel, mannose and alanine pellets during the ‘international intercomparison of criticality dosimetry techniques’ at the SILENE reactor ...
BARTOLOTTA, Antonio +5 more
core +1 more source
Proposed values for diagnostic reference levels in intraoral dental radiography in Serbia [PDF]
Values for diagnostic reference levels are proposed for intraoral dental radiography in the Republic of Serbia. Proposed numbers for diagnostic reference levels were based on measurements on 119 intraoral units in clinical settings for an adult ...
Mirkov Zoran M. +2 more
doaj +1 more source
ABSTRACT Background Procedural and clinical outcomes in patients with obesity undergoing catheter ablation for atrial fibrillation (AF) have been mixed. Clinical data in the context of pulsed field ablation (PFA) are currently limited in this patient cohort.
Francis J. Ha +6 more
wiley +1 more source
γ-H2AX foci as in vivo effect biomarker in children emphasize the importance to minimize x-ray doses in paediatric CT imaging [PDF]
Objectives: Investigation of DNA damage induced by CT x-rays in paediatric patients versus patient dose in a multicentre setting. Methods: From 51 paediatric patients (median age, 3.8 years) who underwent an abdomen or chest CT examination in one of the
A. De Backer +9 more
core +2 more sources
Efficient Charge Transport in Zero‐Dimensional Perovskite for Ultrahigh‐Sensitivity X‐Ray Detection
A novel mono‐octahedral 0D Bi‐based Dpy3Bi2I12 perovskite strengthens the internal hydrogen bonds and forms a quasi‐2D lattice, exhibits exceptional charge transport and mobility, achieving high X‐ray sensitivity and ultralow‐dose imaging, and setting a new benchmark for 0D detector performance.
Xin Song +16 more
wiley +1 more source
Jing Zeng,1,2 Pengpeng Qu,1 Qingsong Pang,2 Ping Wang2 1Department of Gynecologic Oncology, Tianjin Central Hospital of Gynecology and Obstetrics, Affiliated Hospital of Nankai University, Tianjin 300100, People’s Republic of China; 2Tianjin ...
Zeng J, Qu P, Pang Q, Wang P
doaj
Establishment of local diagnostic reference levels for typical radiography examinations in the west region of Croatia [PDF]
Majority of health institutions in Croatia do not have medical physicists in diagnostic radiology. Regarding this, in the west region of Croatia collaboration between public health institution and University Hospital Rijeka was initiated in 2015. Quality
Šegota Doris +2 more
doaj +1 more source
ABSTRACT Background and Aims The International Commission on Radiological Protection emphasizes dose optimization for pediatric patients due to their higher radiosensitivity. Establishing diagnostic reference levels (DRLs) supports this goal during radiological examinations.
O. L. Lackay +2 more
wiley +1 more source