Results 41 to 50 of about 8,576 (208)
Characterization of a new radiochromic film (LD-V1) using mammographic beam qualities
Purpose: Radiochromic film (RCF) is a detector that can obtain a two-dimensional dose distribution with high resolution; it is widely used in medical and industrial fields. Several types of RCFs exist based on their application.
Erika Nakajima, Hitoshi Sato
doaj +1 more source
A survey of short-term and long-term stability of tube parameters in a mammography unit [PDF]
In order to set up a successful mammography screening program in the Republic of Srpska, a Siemens Mammomat 1000 X-ray machine was selected for analysis as the said mammography system is widely used in clinical practice.
Praskalo Jovica Ž. +4 more
doaj +1 more source
Research on the Absolute Measurement Methodology of Air Kerma for N-60~N-350 X-Rays
With the rapid development of nuclear technology applications,the demand for medium- to high-energy X-rays has been increasing substantially,accompanied by urgent requirements for absolute measurement capabilities and measurement ranges of air kerma ...
Yurun WANG +4 more
doaj +1 more source
Procedural Outcome of Modern Percutaneous Coronary Intervention in Proximal Chronic Total Occlusions
ABSTRACT Background Long‐term outcome in patients with chronic total occlusions (CTO) depends on the target vessel and proximity of the lesion. Aims To investigate of the target vessel was associated with procedural efficacy and safety in patients with proximal CTO lesions.
Emil N. Holck +21 more
wiley +1 more source
Use of XR-QA2 radiochromic films for quantitative imaging of a synchrotron radiation beam [PDF]
This work investigates the use of XR-QA2 radiochromic films for quantitative imaging of a synchrotron radiation (SR) beam. Pieces (200 7 30 mm2) of XR-QA2 film were irradiated in a plane transverse to the beam axis, at the SYRMEP beamline at ELETTRA ...
Di Lillo, F. +8 more
core +1 more source
Interventional Radiology (IR) plays a major role in neurology. It has several advantages, such as avoiding higher risk surgeries and reducing hospital stay.
Raquel Nascimento Assimos +1 more
doaj +1 more source
Two Central Nervous System Tumors in One Catheter Lab: Time to Rethink Radiation Protection
ABSTRACT Background Very little research has been done on the possible effects that repeated, frequent, and low‐dose ionizing radiation exposure has on the long‐term health of interventional cardiologists. Aims Following the diagnosis in the same year of two central nervous system tumors in two operators working in the same catheter laboratory, we ...
James R. Bentham, John D. R. Thomson
wiley +1 more source
Twelve high schools in Japan (of which six are in Fukushima Prefecture), four in France, eight in Poland and two in Belarus cooperated in the measurement and comparison of individual external doses in 2014.
Adachi, N. +232 more
core +3 more sources
This paper deals with the determination of the radiation quality correction factor (kQ) well-type ionization chamber for the measurement of Co-60 brachytherapy.
Assef Firnando F +3 more
doaj +1 more source
Patient Dose Optimisation of Abdominopelvic Protocols During X‐Ray Imaging
This study evaluates organ doses in abdominopelvic radiography for both erect and supine positions, addressing dose optimisation concerns in Ghana. Using CalDose X and thermoluminescence dosimeters, organ doses and image quality were analysed, revealing significant dose reductions with optimised exposure parameters (70 kVp, 10 mAs, 110 cm FDD).
Emmanuel Ekem‐Ferguson +3 more
wiley +1 more source

