Is it possible to reduce radiation exposure during transcatheter atrial septal defect closure in children?

open access: yesTürk Kardiyoloji Derneği Arşivi, 2020
Objective: Cardiac catheterization continues to be a major source of radiation exposure for patients with congenital heart disease. As children are more prone to both deterministic and stochastic effects of radiation, every effort should be made to ...
İbrahim Cansaran Tanıdır   +5 more
doaj   +1 more source

Development of an optically stimulated luminescence radiometer based on sodium chloride and gold nanoparticles for improving radiation detection in radiography

open access: yesJournal of Applied Clinical Medical Physics, Volume 27, Issue 5, May 2026.
Abstract Purpose To evaluate sodium chloride doped with gold nanoparticles (NaCl + GNPs) as a low‐cost, reusable optically stimulated luminescence (OSL) material for diagnostic radiology, and to benchmark its luminescence performance against the commercial standard, aluminum oxide doped with carbon (Al2O3:C).
Mus'ab S Alkasasbeh   +7 more
wiley   +1 more source

Infrared Nanocrystals for Space Application: Hardness to Irradiations

open access: yesAdvanced Functional Materials, Volume 36, Issue 37, 7 May 2026.
This article investigates infrared HgTe nanocrystals under X‐ray and ion irradiation, revealing remarkable radiation hardness. It uncovers distinct degradation mechanisms and shows that the nanomaterial outperforms integrated electronics. The results position colloidal nanocrystals as promising candidates for resilient space and harsh‐environment ...
Alexandre Neyret   +22 more
wiley   +1 more source

Proposed values for diagnostic reference levels in intraoral dental radiography in Serbia [PDF]

open access: yesNuclear Technology and Radiation Protection
Values for diagnostic reference levels are proposed for intraoral dental radiography in the Republic of Serbia. Proposed numbers for diagnostic reference levels were based on measurements on 119 intraoral units in clinical settings for an adult ...
Mirkov Zoran M.   +2 more
doaj   +1 more source

Procedural Outcome of Modern Percutaneous Coronary Intervention in Proximal Chronic Total Occlusions

open access: yesCatheterization and Cardiovascular Interventions, Volume 107, Issue 6, Page 2041-2049, May 1, 2026.
ABSTRACT Background Long‐term outcome in patients with chronic total occlusions (CTO) depends on the target vessel and proximity of the lesion. Aims To investigate of the target vessel was associated with procedural efficacy and safety in patients with proximal CTO lesions.
Emil N. Holck   +21 more
wiley   +1 more source

Air-kerma evaluation at the maze entrance of HDR brachytherapy facilities

open access: yesJournal of Radiological Protection, 2014
In the absence of procedures for evaluating the design of brachytherapy (BT) facilities for radiation protection purposes, the methodology used for external beam radiotherapy facilities is often adapted. The purpose of this study is to adapt the NCRP 151 methodology for estimating the air-kerma rate at the door in BT facilities.
Pujades, M.C.   +6 more
openaire   +4 more sources

Microdosimetry in BNCT

open access: yes
Precision Radiation Oncology, EarlyView.
Gustavo A. Santa Cruz
wiley   +1 more source

Advancing iris melanoma brachytherapy: Eye plaque models for Monte Carlo simulations and 3D dosimetric datasets

open access: yesMedical Physics, Volume 53, Issue 5, May 2026.
Abstract Purpose To develop and benchmark eye plaque models for Monte Carlo (MC) simulation of iris melanoma brachytherapy and to develop a database of 3D dose distributions for the iris plaques containing 103Pd${}^{103}{\rm Pd}$, 125I${}^{125}{\rm I}$, and 131Cs${}^{131}{\rm Cs}$ seeds.
Marwa Djedouani   +3 more
wiley   +1 more source

Establishment of local diagnostic reference levels for typical radiography examinations in the west region of Croatia [PDF]

open access: yesNuclear Technology and Radiation Protection, 2019
Majority of health institutions in Croatia do not have medical physicists in diagnostic radiology. Regarding this, in the west region of Croatia collaboration between public health institution and University Hospital Rijeka was initiated in 2015. Quality
Šegota Doris   +2 more
doaj   +1 more source

Monte Carlo modeling of the field size dependency for thin window plane‐parallel chambers in kilovoltage X‐ray reference dosimetry

open access: yesMedical Physics, Volume 53, Issue 5, May 2026.
Abstract Background Clinical dosimetry for kV X‐ray radiotherapy beams requires calibrated ionization chambers. When the clinical field size differs from the field size used for chamber calibration, in‐air measurements result in a different magnitude of scatter from the detector stem or body housing affecting the sensitive volume.
Fayz Kadeer   +2 more
wiley   +1 more source