[Progress in applications of ambient ionization mass spectrometry for lipids identification]. [PDF]
Wang XR, Yin YY, Ouyang J, Na N.
europepmc +1 more source
Through the introduction of a niobium oxide layer into a hafnia ferroelectric capacitor stack, we build a memory device with a strong imprint effect. This imprint leads to a millisecond retention loss that can be tuned by the programming conditions that can be utilized as a scalable, analog hardware time constant for bio‐inspired temporal computing ...
Luca Fehlings +3 more
wiley +1 more source
Laser Printer Printed Ion Sources for Ambient Ionization Mass Spectrometric Analysis of Volatiles and Semivolatiles. [PDF]
Chiu CP, Chen YC.
europepmc +1 more source
Influence of Top Electrode Metal on Resistive Switching in Multilayer MOCVD MoS2 Memristors
MoS2 memristors typically use evaporated noble metal electrodes. This study compares Pd, Ni, and Al electrodes and sputtered versus evaporated deposition. Pd is passive, while Ni damages MoS2, yielding poor switching. Sputtered Al enables reproducible ECM‐type switching with 95% yield, whereas evaporated Al forms an interfacial oxide that suppresses ...
Dennis Braun +15 more
wiley +1 more source
Novel plasma-based ambient desorption/ionization source
周囲プラズマベースの周囲脱離/イオン化ソースにより、従来の大気圧イオン化では不可能な周囲条件下でのサンプルの直接分析が可能になります。これにより、面倒な準備と、多くの有害で複雑なサンプルの分析用質量分析計への導入が解消されます。既存のプラズマベースのアンビエント脱離/イオン化ソースは、通常、2つの電極間にキロヘルツから数メガヘルツの範囲の周波数で直流(DC)または交流(AC)電圧を印加することによって形成されます。この研究では、新しいプラズマベースの周囲脱離/イオン化は、13.56 MHz ...
Soriano, Joey Kim Tumbali
core
Performance Comparison of Ambient Ionization Techniques Using a Single Quadrupole Mass Spectrometer for the Analysis of Amino Acids, Drugs, and Explosives. [PDF]
Mathias S +8 more
europepmc +1 more source
Two series of self‐doped conjugated polyelectrolytes are synthesized from a non‐self‐dopable building block 3MEEET and a self‐dopable building‐block 3HOT−[TMA+] or 3HOT−[SO3H] enabling precise control over the degree of self‐doping, which in turn directly governs the threshold voltage (VT) in OECTs over a wide range of 700 mV.
Julian Hungenberg +7 more
wiley +1 more source
Rapid Characterization of Undeclared Pharmaceuticals in Herbal Preparations by Ambient Ionization Mass Spectrometry for Emergency Care. [PDF]
Lee CW +7 more
europepmc +1 more source
Organic permeable base transistors are shown to benefit from balanced control of the semiconductor layers above and below the permeable base. Simulations and experiments indicate that the top semiconductor layer affects charge injection and lateral transfer length, while the bottom layer modulates the collector‐induced short‐channel effects.
Sun‐Woo Jo +4 more
wiley +1 more source
Selectivity of Explosives Analysis with Ambient Ionization Single Quadrupole Mass Spectrometry: Implications for Trace Detection. [PDF]
Mathias S +8 more
europepmc +1 more source

