Results 31 to 40 of about 623,539 (276)
Shapley Value as a Quality Control for Mass Spectra of Human Glioblastoma Tissues
The automatic processing of high-dimensional mass spectrometry data is required for the clinical implementation of ambient ionization molecular profiling methods. However, complex algorithms required for the analysis of peak-rich spectra are sensitive to
Denis S. Zavorotnyuk +7 more
doaj +1 more source
Ambient Ionization: A Dream for the Surgical Oncologist? [PDF]
One challenge for the cancer surgeon is to consistently distinguish tumor from healthy tissue and definitively remove the tumor with clean margins. The pathologist plays a key role in confirming the identity of the tissue removed, but it takes time to remove the sample, send it to the pathologist, and receive an expert analysis.
Vikram Sheel, Kumar, Molly, Webster
openaire +2 more sources
Modern technical evolution made mass spectrometry (MS) an absolute must for analytical chemistry in terms of application range, detection limits and speed.
Andreas Kiontke +2 more
doaj +1 more source
A Comparative Study of Some Values of ionization constants of Oximes and Phenolic Acids Derived fromِ Aliphatic and Aromatic Carbonyl Compounds [PDF]
The project includes on the determination of ionization constants kn for thirteen acidic new imines as derived form aliphatic and aromatic ketones with different aldehydes, where n is the number of acid.
Adil Azooz, Maathir Al-Zubaidy
doaj +1 more source
Ex-vivo molecular profiling has recently emerged as a promising method for intraoperative tissue identification, especially in neurosurgery. The short-term storage of resected samples at room temperature is proposed to have negligible influence on the ...
Stanislav I. Pekov +6 more
doaj +1 more source
Easy ambient sonic-spray ionization mass spectrometry for tissue imaging
FAPESP - FUNDAÇÃO DE AMPARO À PESQUISA DO ESTADO DE SÃO PAULOCAPES - COORDENAÇÃO DE APERFEIÇOAMENTO DE PESSOAL DE NÍVEL SUPERIORTwo spray-based ambient ionization methods, desorption electrospray ionization (DESI) and easy ambient sonic-spray ionization (
Alberice, Rosana M. +2 more
core +2 more sources
A Chemical Ionization Mass Spectrometer for ambient measurements of Ammonia [PDF]
This study presents a chemical ionization mass spectrometer (CIMS) for fast response, in-situ measurements of gas phase ammonia (NH<sub>3</sub>). The NH<sub>3</sub> background level detected with the CIMS ranged between 0.3–1 ppbv,
D. R. Benson +3 more
doaj +1 more source
Ambient mass spectrometry-based approaches have found application in biology and medicine. Here the authors report a mass spectrometric imaging method (ambient nanoPALDI) for live hippocampal tissues, based on gold nanorodassisted femtosecond laser ...
Jae Young Kim +5 more
doaj +1 more source
Contrast optimization of mass spectrometry imaging (MSI) data visualization by threshold intensity quantization (TrIQ) [PDF]
Mass spectrometry imaging (MSI) enables the unbiased characterization of surfaces with respect to their chemical composition. In biological MSI, zones with differential mass profiles hint towards localized physiological processes, such as the tissue ...
Ignacio Rosas-Román, Robert Winkler
doaj +2 more sources

