Results 101 to 110 of about 51,918 (342)
A self‐sustaining solar photoelectrochemical cell (SS‐PEC) is developed to recover uranium from aqueous UO22+ with concurrent organic oxidation and electricity production. The monolithical photoanode directly captures electrons from organic compounds, leading to the oxidation of organic compounds and the decomposition of uranium‐organic complexes ...
Yumei Wang +7 more
wiley +1 more source
Micropatterned Biphasic Printed Electrodes for High‐Fidelity on‐Skin Bioelectronics
Micropatterned biphasic printed electrodes achieve unprecedented skin conformity and low impedance by combining liquid‐metal droplets with microstructured 3D lattices. This scalable approach enables high‐fidelity detection of ECG, EMG, and EEG signals, including alpha rhythms from the forehead, with long‐term comfort and stability.
Manuel Reis Carneiro +4 more
wiley +1 more source
Design of Gm-C wavelet filter for on-line epileptic EEG detection [PDF]
Copyright © 2019 The Institute of Electronics, Information and Communication EngineersAnalog filter implementation of continuous wavelet transform is considered as a promising technique for on-line spike detection applied in wearable electroencephalogram
He, Yigang +4 more
core +2 more sources
Electric control of magnetic tunnel junctions offers a path to drastically reduce the energy requirements of the device. Electric field control of magnetization can be realized in a multitude of ways. These mechanisms can be integrated into existing spintronic devices to further reduce the operational energy.
Will Echtenkamp +7 more
wiley +1 more source
A symmetric 8T2R NVSRAM with autosave function
This letter presented a symmetric 8T2R NVSRAM with autosave function. By efficiently multiplexing the node voltages, the control of the nonvolatile memristor and the isolation of the data node from the memristor are achieved, which ensures an ...
Bowen Su +3 more
doaj +1 more source
A Single-Chip CMOS Pulse Oximeter with On-Chip Lock-In Detection
Pulse oximetry is a noninvasive and continuous method for monitoring the blood oxygen saturation level. This paper presents the design and testing of a single-chip pulse oximeter fabricated in a 0.35 µm CMOS process.
Diwei He +8 more
doaj +1 more source
A Reconfigurable Mixed-signal Implementation of a Neuromorphic ADC
We present a neuromorphic Analogue-to-Digital Converter (ADC), which uses integrate-and-fire (I&F) neurons as the encoders of the analogue signal, with modulated inhibitions to decohere the neuronal spikes trains. The architecture consists of an analogue
Hamilton, Tara Julia +5 more
core +1 more source
Nonlinear switched-current CMOS IC for random signal generation [PDF]
A nonlinear switched-current circuit is presented that implements a chaotic algorithm for the generation of broadband, white analogue noise. The circuit has been fabricated in a double-metal, single-poly 1.6µm CMOS technology and uses a novel, highly ...
Delgado Restituto, Manuel +2 more
core +1 more source
[001]‐oriented Sb2Se3 film with improved crystallinity and adjusted composition is achieved via a new thermal treatment approach consisting of preliminary annealing of the Sb layer before its selenization. The findings of this work demonstrate enhanced charge carriers' transportation, a stable performance, and an improvement of H2 generation from ...
Magno B. Costa +7 more
wiley +1 more source
Open‐source floating‐gate cell for analogue synapses
The floating‐gate transistor is commonly employed as a non‐volatile memory device, leveraging a floating node at its gate to store electrical charge over extended periods.
Matthew Chen +2 more
doaj +1 more source

