Back analysis of pile and anchor retaining structure based on BOTDA distributed optical fiber sensing technology [PDF]

open access: yesE3S Web of Conferences, 2021
In order to understand the deformation law and internal force distribution characteristics of the pile-anchor retaining structure in deep foundation pit engineering, the stress of the pile-anchor retaining system in the process of foundation pit ...
Wang Xin   +3 more
doaj   +2 more sources

Wind Fragility for Sign Structure in Korea with Chemical Anchor Connection

open access: yesMATEC Web of Conferences, 2018
Damage to domestic facilities by strong winds and typhoon is on the rise in recent year. Typical sign structure used in Korea is found on the edge of concrete building, which could be easily affected by strong winds. Therefore, this study focused on sign
Sim Viriyavudh   +2 more
doaj   +2 more sources

Centrifugal Model Test of Multi-Level Slope under Combined Support of Pile-Anchor and Frame-Anchor

open access: yesBuildings
The combination support structure of pile-anchor and frame-anchor is widely used in multi-level slope engineering, but the relevant theoretical research lags behind engineering practice.
Kuibin Yang   +4 more
doaj   +2 more sources

Building Capacity as Anchor Institutions: Infrastructure, Structure, and Strategy [PDF]

open access: yesMetropolitan Universities, 2019
As campuses embrace their role as anchor institutions, considerations should be given to the role of infrastructure, structure, and strategy. This article differentiates between infrastructure and organizational structure then identifies implications for
Kristin Elise Norris, H. Anne Weiss
doaj   +3 more sources

Understanding the Internal Structure of Daily Activity Space from Anchor Regions: Evidence from Long-Time-Series Mobile Signaling Data

open access: yesISPRS International Journal of Geo-Information
Activity space represents the spatiotemporal interaction between individuals and their environment. While most studies measure potential activity space using short-term data, few have defined or measured its actual internal structure.
Xueyao Luo   +3 more
doaj   +2 more sources

Development and Test of Internal-Cutting Down-Attached Anchor

open access: yesShiyou jixie
To solve the problems of low cutting efficiency and unstable cutting fracture quality caused by severe vibration and eccentric rotation of the cutter device in downhole hydraulic cutting operation of tubing and casing, a cutter down-attached anchor tool ...
Li Yong   +6 more
doaj   +2 more sources

Influence of Slope Amplification on the Pile Dynamic Behavior Based on the Data Mining Method

open access: yesFrontiers in Earth Science, 2022
In this article, a centrifuge shaking table model test of anchored stabilizing piles for strengthening landslides was established, and the dynamic response characteristics of the pile–anchor–slope under earthquake action were analyzed.
Yu Wang   +4 more
doaj   +1 more source

H-Shaped Radial Phononic Crystal for High-Quality Factor on Lamb Wave Resonators

open access: yesSensors, 2023
In this paper, a novel H-shaped radial phononic crystal (H-RPC) structure is proposed to suppress the anchor loss of a Lamb wave resonator (LWR), which has an ultra-high frequency (UHF) and ultra-wideband gap characteristics. Compared to previous studies
Weitao He   +5 more
doaj   +1 more source

rigid retaining wall, earth pressure, model indeterminacy, variational limit equilibrium method

open access: yesYantu gongcheng xuebao, 2017
The anchor technology in China's standards has some room for improvement compared with the foreign ones. Based on the latest standards of European Union, USA and Japan, some suggestions are put forward: (1) An anchor structure division method is proposed,
FU Wen-guang 1, HU Jian-lin 2, ZHOU Jian-ming 3
doaj   +1 more source

Experimental study on internal monitoring structure of a new prestressed anchor cable

open access: yesYantu gongcheng xuebao, 2020
On account of their difficult internal stress monitoring, a new type of internal stress monitoring structure for pre-stressed anchor cables is developed and then tested by the destructive tension tests and the repeated tension tests under multi-levelload.